Volgen
Niclas Börlin
Niclas Börlin
Department of Computing Science
Geverifieerd e-mailadres voor cs.umu.se
Titel
Geciteerd door
Geciteerd door
Jaar
Guidelines for standardization of radiostereometry (RSA) of implants
ER Valstar, R Gill, L Ryd, G Flivik, N Börlin, J Kärrholm
Acta orthopaedica 76 (4), 563-572, 2005
6252005
Experimental assessment of precision and accuracy of radiostereometric analysis for the determination of polyethylene wear in a total hip replacement model
CR Bragdon, H Malchau, X Yuan, R Perinchief, J Kärrholm, N Börlin, ...
Journal of Orthopaedic Research 20 (4), 688-695, 2002
1812002
The precision of radiostereometric measurements. Manual vs. digital measurements
N Börlin, T Thien, J Kärrholm
Journal of biomechanics 35 (1), 69-79, 2002
1522002
RSA wear measurements with or without markers in total hip arthroplasty
N Börlin, SM Röhrl, CR Bragdon
Journal of biomechanics 39 (9), 1641-1650, 2006
1002006
Estimation of tree stem attributes using terrestrial photogrammetry with a camera rig
M Forsman, N Börlin, J Holmgren
Forests 7 (3), 61, 2016
912016
No increased migration in cups with ceramic-on-ceramic bearing: an RSA study
Z Zhou, MG Li, N Börlin, DJ Wood, B Nivbrant
Clinical Orthopaedics and Related Research® 448, 39-45, 2006
522006
Radiostereometric evaluation of hip implant design and surface finish: micromotion of cemented femoral stems
J Kärrholm, B Nivbrant, J Thanner, C Anderberg, N Börlin, P Herberts, ...
52*2000
Accuracy of radiographic and radiostereometric wear measurement of different hip prostheses an experimental study
T Schewelov, L Sanzén, N Börlin, P Markusson, I Önsten
Acta Orthopaedica Scandinavica 75 (6), 691-700, 2004
492004
Open source and independent methods for bundle adjustment assessment in close-range UAV photogrammetry
A Murtiyoso, P Grussenmeyer, N Börlin, J Vandermeerschen, T Freville
Drones 2 (1), 3, 2018
432018
Bundle adjustment with and without damping
N Börlin, P Grussenmeyer
The Photogrammetric Record 28 (144), 396-415, 2013
412013
Validation of a low-dose hybrid RSA and fluoroscopy technique: Determination of accuracy, bias and precision
J Ioppolo, N Börlin, C Bragdon, M Li, R Price, D Wood, H Malchau, ...
Journal of biomechanics 40 (3), 686-692, 2007
372007
Bias of cylinder diameter estimation from ground-based laser scanners with different beam widths: A simulation study
M Forsman, N Börlin, K Olofsson, H Reese, J Holmgren
ISPRS journal of photogrammetry and remote sensing 135, 84-92, 2018
332018
Estimation of tree stem attributes using terrestrial photogrammetry
M Forsman, N Börlin, J Holmgren
XXII ISPRS Congress in Melbourne, Australia, Aug 25-Sep 1, 2012, B5-261-B5-265, 2012
322012
Camera calibration using the damped bundle adjustment toolbox
N Börlin, P Grussenmeyer
ISPRS Technical Commission V Symposium, 23–25 June 2014, Riva del Garda …, 2014
222014
Model-based measurements in digital radiographs
N Börlin
Univ., 2000
182000
GALS–Gradient Analysis by Least Squares
M Hamrin, K Rönnmark, N Börlin, J Vedin, A Vaivads
Annales Geophysicae 26 (11), 3491-3499, 2008
172008
Comparison of resection–intersection algorithms and projection geometries in radiostereometry
N Börlin
ISPRS journal of photogrammetry and remote sensing 56 (5-6), 390-400, 2002
172002
Improving underwater accuracy by empirical weighting of image observations
F Menna, E Nocerino, P Drap, F Remondino, A Murtiyoso, ...
The International Archives of the Photogrammetry, Remote Sensing and Spatial …, 2018
132018
Pros and cons of constrained and unconstrained formulation of the bundle adjustment problem
N Börlin, P Grussenmeyer, J Eriksson, P Lindstrom
XXth Congress of the International Society for Photogrammetry and Remote …, 2004
102004
Photogrammetric calibration of image sequences acquired with a rotating camera
F Remondino, N Börlin
ISPRS working group V/1, Panoramic Photogrammetry Workshop, Dresden, Germany …, 2004
102004
Het systeem kan de bewerking nu niet uitvoeren. Probeer het later opnieuw.
Artikelen 1–20