Follow
Anoop Bharathan
Anoop Bharathan
Unknown affiliation
Verified email at serc.res.in
Title
Cited by
Cited by
Year
Application of fuzzy sets for estimating service life of reinforced concrete structural members in corrosive environments
MB Anoop, KB Rao, T Rao
Engineering structures 24 (9), 1229-1242, 2002
592002
Conversion of probabilistic information into fuzzy sets for engineering decision analysis
MB Anoop, KB Rao, S Gopalakrishnan
Computers & structures 84 (3-4), 141-155, 2006
472006
Safety assessment of austenitic steel nuclear power plant pipelines against stress corrosion cracking in the presence of hybrid uncertainties
MB Anoop, KB Rao, N Lakshmanan
International Journal of Pressure Vessels and Piping 85 (4), 238-247, 2008
452008
A refined methodology for durability‐based service life estimation of reinforced concrete structural elements considering fuzzy and random uncertainties
MB Anoop, BK Raghuprasad, K Balaji Rao
Computer‐Aided Civil and Infrastructure Engineering 27 (3), 170-186, 2012
432012
Early age creep of cement paste-Governing mechanisms and role of water-A microindentation study
S Mallick, MB Anoop, KB Rao
Cement and Concrete Research 116, 284-298, 2019
332019
Application of fuzzy sets for remaining life assessment of corrosion affected reinforced concrete bridge girders
MB Anoop, K Balaji Rao
Journal of Performance of Constructed Facilities 21 (2), 166-171, 2007
272007
Probabilistic failure analysis of austenitic nuclear pipelines against stress corrosion cracking
C Priya, KB Rao, MB Anoop, N Lakshmanan, V Gopika, HS Kushwaha, ...
Proceedings of the Institution of Mechanical Engineers, Part C: Journal of …, 2005
222005
Creep of cement paste containing fly ash-an investigation using microindentation technique
S Mallick, MB Anoop, KB Rao
Cement and Concrete Research 121, 21-36, 2019
212019
Probabilistic fatigue life analysis of welded steel plate railway bridge girders using S–N curve approach
KB Rao, MB Anoop, G Raghava, M Prakash, A Rajadurai
Proceedings of the Institution of Mechanical Engineers, Part O: Journal of …, 2013
182013
Risk-based remaining life assessment of corrosion affected reinforced concrete structural members
K Balaji Rao, MB Anoop, N Lakshmanan, S Gopalakrishnan, T Appa Rao
Structural Engineering Research Center, Chennai, 2004
182004
Nanoindentation for evaluation of properties of cement hydration products
S Sasmal, MB Anoop
Nanotechnology in Eco-efficient Construction, 141-161, 2019
162019
Time‐variant reliability analysis of RC bridge girders subjected to corrosion–shear limit state
AP Vatteri, K Balaji Rao, AM Bharathan
Structural Concrete 17 (2), 162-174, 2016
162016
An improved method for estimation of elastic lateral stiffness of brick masonry shear walls with openings
SR Balasubramanian, K Balaji Rao, D Basu, MB Anoop, ...
KSCE Journal of Civil Engineering 15, 281-293, 2011
162011
A methodology for durability-based service life design of reinforced concrete flexural members
MB Anoop, K Balaji Rao, T Appa Rao
Magazine of Concrete Research 55 (3), 289-303, 2003
142003
Determination of bounds on failure probability in the presence of hybrid uncertainties
MB Anoop, K Balaji Rao
Sadhana 33, 753-765, 2008
122008
A study on clustered and de-clustered world-wide earthquake data using GR recurrence law
JDR Joseph, KB Rao, MB Anoop
International Journal of Earth Sciences and Engineering 4, 178-182, 2011
92011
Performance evaluation of corrosion-affected reinforced concrete bridge girders using Markov chains with fuzzy states
MB Anoop, K Balaji Rao
Sādhanā 41, 887-899, 2016
82016
Model for compressive strength development of OPC concrete and fly ash concrete with time
GS Vijaya Bhaskara, K Balaji Rao, MB Anoop
Magazine of Concrete Research 70 (11), 541-557, 2018
72018
Prediction of basic creep of concrete-semi-empirical model based on adaptive link mechanism
S Mallick, MB Anoop, KB Rao
ACI Materials Journal 114 (1), 29, 2017
72017
Seismic damage estimation of reinforced concrete framed structures affected by chloride-induced corrosion
MB Anoop, KB Rao
Earthquakes and Structures 9 (4), 851-873, 2015
72015
The system can't perform the operation now. Try again later.