Volgen
Marcos Donolo
Marcos Donolo
SEL inc
Geverifieerd e-mailadres voor vt.edu - Homepage
Titel
Geciteerd door
Geciteerd door
Jaar
Anti-islanding today, successful islanding in the future
J Mulhausen, J Schaefer, M Mynam, A Guzmán, M Donolo
2010 63rd Annual Conference for Protective Relay Engineers, 1-8, 2010
1282010
Advanced real-time synchrophasor applications
EO Schweitzer, D Whitehead, A Guzman, Y Gong, M Donolo
proceedings of the 35th Annual Western Protective Relay Conference, Spokane, WA, 2008
1072008
Voltage unbalance and harmonic distortion effects on induction motor power, torque and vibrations
P Donolo, G Bossio, C De Angelo, G García, M Donolo
Electric power systems research 140, 866-873, 2016
812016
Detecting broken rotor bars with zero-setting protection
C Pezzani, P Donolo, G Bossio, M Donolo, A Guzmán, SE Zocholl
IEEE Transactions on Industry Applications 50 (2), 1373-1384, 2013
722013
Distributed bus differential protection using time-stamped data
MA Donolo, A Guzman-Casillas, EO Schweitzer III
US Patent 8,405,944, 2013
712013
Systems and method for obtaining a load model and related parameters based on load dynamics
EO Schweitzer III, MA Donolo, DE Whitehead
US Patent 8,706,309, 2014
632014
State and topology processor
EO Schweitzer III, MA Donolo, A Guzman-Casillas
US Patent 7,856,327, 2010
512010
Mitigating the aurora vulnerability with existing technology
D Salmon, M Zeller, A Guzmán, V Mynam, M Donolo
36th Annual western protection relay conference, 2009
342009
A fast quality assessment algorithm for phasor measurements
MA Donolo, VA Centeno
IEEE transactions on power delivery 20 (4), 2407-2413, 2005
322005
Systems and methods for monitoring and controlling electrical system stability
MA Donolo
US Patent 8,554,385, 2013
272013
Derating of induction motors due to power quality issues considering the motor efficiency class
PD Donolo, CM Pezzani, GR Bossio, CH De Angelo, MA Donolo
IEEE Transactions on Industry Applications 56 (2), 961-969, 2020
262020
Advantages of synchrophasor measurements over SCADA measurements for power system state estimation
M Donolo
SEL application note 2010, 2006
252006
Islanding detection in an electrical power delivery system
A Guzman-Casillas, MV Mynam, MA Donolo
US Patent 8,346,402, 2013
192013
Detection of broken rotor bar conditions in a motor using maximum current magnitude and average current magnitude
MA Donolo
US Patent 9,151,802, 2015
162015
Improve transmission fault location and distance protection using accurate line parameters
HE Prado-Félix, VH Serna-Reyna, MV Mynam, M Donolo, A Guzmán
GRIDTECH 2015, 13, 2015
142015
Accuracy Limits for Synchrophasor Measurements and the IEEE standard
MA Donolo, VA Centeno
IEEE transactions on Power Delivery 23 (1), 504-505, 2008
142008
Shaft mounted monitor for rotating machinery
MA Donolo
US Patent 10,063,124, 2018
122018
Monitoring and mitigating the voltage collapse problem in the Natal network
M Donolo, M Venkatasubramanian, A Guzman, F de Villiers
2009 IEEE/PES Power Systems Conference and Exposition, 1-5, 2009
102009
Performance of synchronous motors loss-of-synchronism protection
M Donolo, P Donolo, S Patel, V Yedidi
2017 Petroleum and Chemical Industry Technical Conference (PCIC), 71-78, 2017
82017
Secure and dependable differential protection for electric power generators
MA Donolo
US Patent 9,660,438, 2017
72017
Het systeem kan de bewerking nu niet uitvoeren. Probeer het later opnieuw.
Artikelen 1–20