Follow
Prof. Dr. Michael J. Schöning
Prof. Dr. Michael J. Schöning
FH Aachen, Institute of Nano- and Biotechnologies
Verified email at fh-aachen.de - Homepage
Title
Cited by
Cited by
Year
Recent advances in biologically sensitive field-effect transistors (BioFETs)
MJ Schöning, A Poghossian
Analyst 127 (9), 1137-1151, 2002
7742002
Epidermal tattoo potentiometric sodium sensors with wireless signal transduction for continuous non-invasive sweat monitoring
AJ Bandodkar, D Molinnus, O Mirza, T Guinovart, JR Windmiller, ...
Biosensors and bioelectronics 54, 603-609, 2014
5562014
Bio FEDs (field‐effect devices): state‐of‐the‐art and new directions
MJ Schöning, A Poghossian
Electroanalysis: An International Journal Devoted to Fundamental and …, 2006
3852006
Possibilities and limitations of label-free detection of DNA hybridization with field-effect-based devices
A Poghossian, A Cherstvy, S Ingebrandt, A Offenhäusser, MJ Schöning
Sensors and Actuators B: Chemical 111, 470-480, 2005
3202005
Fabrication of poly (methyl methacrylate) microfluidic chips by atmospheric molding
A Muck, J Wang, M Jacobs, G Chen, MP Chatrathi, V Jurka, Z Výborný, ...
Analytical chemistry 76 (8), 2290-2297, 2004
1782004
Rapid methods and sensors for milk quality monitoring and spoilage detection
A Poghossian, H Geissler, MJ Schöning
Biosensors and Bioelectronics 140, 111272, 2019
1762019
The light-addressable potentiometric sensor for multi-ion sensing and imaging
T Yoshinobu, H Iwasaki, Y Ui, K Furuichi, Y Ermolenko, Y Mourzina, ...
Methods 37 (1), 94-102, 2005
1752005
Porous silicon as a substrate material for potentiometric biosensors
M Thust, MJ Schöning, S Frohnhoff, R Arens-Fischer, P Kordos, H Lüth
Measurement Science and Technology 7 (1), 26, 1996
1741996
Wearable electrochemical sensors for in situ analysis in marine environments
K Malzahn, JR Windmiller, G Valdés-Ramírez, MJ Schöning, J Wang
Analyst 136 (14), 2912-2917, 2011
1552011
Label‐free sensing of biomolecules with field‐effect devices for clinical applications
A Poghossian, MJ Schöning
Electroanalysis 26 (6), 1197-1213, 2014
1532014
Label-free detection of single nucleotide polymorphisms utilizing the differential transfer function of field-effect transistors
S Ingebrandt, Y Han, F Nakamura, A Poghossian, MJ Schöning, ...
Biosensors and Bioelectronics 22 (12), 2834-2840, 2007
1532007
“All-in-one” solid-state device based on a light-addressable potentiometric sensor platform
T Wagner, T Yoshinobu, C Rao, R Otto, MJ Schöning
Sensors and Actuators B: Chemical 117 (2), 472-479, 2006
1532006
Amperometric PDMS/glass capillary electrophoresis-based biosensor microchip for catechol and dopamine detection
MJ Schöning, M Jacobs, A Muck, DT Knobbe, J Wang, M Chatrathi, ...
Sensors and Actuators B: Chemical 108 (1-2), 688-694, 2005
1412005
A dual amperometric/potentiometric FIA-based biosensor for the distinctive detection of organophosphorus pesticides
MJ Schöning, R Krause, K Block, M Musahmeh, A Mulchandani, J Wang
Sensors and Actuators B: Chemical 95 (1-3), 291-296, 2003
1372003
CIP (cleaning-in-place) suitable “non-glass” pH sensor based on a Ta2O5-gate EIS structure
MJ Schöning, D Brinkmann, D Rolka, C Demuth, A Poghossian
Sensors and Actuators B: Chemical 111, 423-429, 2005
1302005
Field-effect devices for detecting cellular signals
A Poghossian, S Ingebrandt, A Offenhäusser, MJ Schöning
Seminars in cell & developmental biology 20 (1), 41-48, 2009
1282009
Passivation and corrosion of microelectrode arrays
G Schmitt, JW Schultze, F Faßbender, G Buß, H Lüth, MJ Schöning
Electrochimica Acta 44 (21-22), 3865-3883, 1999
1251999
“Playing around” with field-effect sensors on the basis of EIS structures, LAPS and ISFETs
MJ Schöning
Sensors 5 (3), 126-138, 2005
1212005
Penicillin detection by means of field-effect based sensors: EnFET, capacitive EIS sensor or LAPS?
A Poghossian, T Yoshinobu, A Simonis, H Ecken, H Lüth, MJ Schöning
Sensors and Actuators B: Chemical 78 (1-3), 237-242, 2001
1202001
Flow injection amperometric detection of OP nerve agents based on an organophosphorus–hydrolase biosensor detector
J Wang, R Krause, K Block, M Musameh, A Mulchandani, MJ Schöning
Biosensors and Bioelectronics 18 (2-3), 255-260, 2003
1132003
The system can't perform the operation now. Try again later.
Articles 1–20