Follow
Benjamin Goldschmidt
Benjamin Goldschmidt
Physics of Molecular Imaging Systems, RWTH Aachen University
Verified email at pmi.rwth-aachen.de - Homepage
Title
Cited by
Cited by
Year
A digital preclinical PET/MRI insert and initial results
B Weissler, P Gebhardt, PM Dueppenbecker, J Wehner, D Schug, ...
IEEE transactions on medical imaging 34 (11), 2258-2270, 2015
1222015
Initial PET performance evaluation of a preclinical insert for PET/MRI with digital SiPM technology
D Schug, C Lerche, B Weissler, P Gebhardt, B Goldschmidt, J Wehner, ...
Physics in Medicine & Biology 61 (7), 2851, 2016
802016
MR compatibility aspects of a silicon photomultiplier-based PET/RF insert with integrated digitisation
B Weissler, P Gebhardt, CW Lerche, J Wehner, T Solf, B Goldschmidt, ...
Physics in Medicine & Biology 59 (17), 5119, 2014
722014
MR-compatibility assessment of the first preclinical PET-MRI insert equipped with digital silicon photomultipliers
J Wehner, B Weissler, PM Dueppenbecker, P Gebhardt, B Goldschmidt, ...
Physics in Medicine & Biology 60 (6), 2231, 2015
712015
Data processing for a high resolution preclinical PET detector based on Philips DPC digital SiPMs
D Schug, J Wehner, B Goldschmidt, C Lerche, PM Dueppenbecker, ...
IEEE Transactions on Nuclear Science 62 (3), 669-678, 2015
472015
SiPM based preclinical PET/MR insert for a human 3T MR: first imaging experiments
V Schulz, B Weissler, P Gebhardt, T Solf, CW Lerche, P Fischer, M Ritzert, ...
2011 IEEE Nuclear Science Symposium Conference Record, 4467-4469, 2011
472011
Design concept of world's first preclinical PET/MR insert with fully digital silicon photomultiplier technology
B Weissler, P Gebhardt, P Düppenbecker, B Goldschmidt, A Salomon, ...
2012 IEEE Nuclear Science Symposium and Medical Imaging Conference Record …, 2012
432012
A self-normalization reconstruction technique for PET scans using the positron emission data
A Salomon, B Goldschmidt, R Botnar, F Kiessling, V Schulz
IEEE transactions on medical imaging 31 (12), 2234-2240, 2012
382012
ToF performance evaluation of a PET insert with Digital Silicon Photomultiplier technology during MR operation
D Schug, J Wehner, PM Dueppenbecker, B Weissler, P Gebhardt, ...
EJNMMI physics 1, 1-2, 2014
37*2014
Towards software-based real-time singles and coincidence processing of digital PET detector raw data
B Goldschmidt, CW Lerche, T Solf, A Salomon, F Kiessling, V Schulz
IEEE Transactions on Nuclear Science 60 (3), 1550-1559, 2013
342013
PET performance and MRI compatibility evaluation of a digital, ToF-capable PET/MRI insert equipped with clinical scintillators
D Schug, J Wehner, PM Dueppenbecker, B Weissler, P Gebhardt, ...
Physics in Medicine & Biology 60 (18), 7045, 2015
332015
Software-based real-time acquisition and processing of PET detector raw data
B Goldschmidt, D Schug, CW Lerche, A Salomon, P Gebhardt, B Weissler, ...
IEEE Transactions on Biomedical Engineering 63 (2), 316-327, 2015
302015
Maximum likelihood based positioning and energy correction for pixelated solid state PET detectors
CW Lerche, T Solf, P Dueppenbecker, B Goldschmidt, PK Marsden, ...
2011 IEEE Nuclear Science Symposium Conference Record, 3610-3613, 2011
152011
Calibration and stability of a SiPM-based simultaneous PET/MR insert
CW Lerche, J Mackewn, B Goldschmidt, A Salomon, P Gebbhardt, ...
Nuclear Instruments and Methods in Physics Research Section A: Accelerators …, 2013
132013
Maximum likelihood positioning and energy correction for scintillation detectors
CW Lerche, A Salomon, B Goldschmidt, S Lodomez, B Weissler, T Solf
Physics in Medicine & Biology 61 (4), 1650, 2016
112016
MR-compatibility study of a preclinical digital PET/MRI insert
J Wehner, B Weissler, P Dueppenbecker, P Gebhardt, B Goldschmidt, ...
EJNMMI physics 1, 1-1, 2014
32014
MR image quality and timing resolution of an analog SiPM based pre-clinical PET/MR Insert
CW Lerche, JE Mackewn, R Ayres, B Weissler, P Gebhardt, T Solf, ...
2012 IEEE Nuclear Science Symposium and Medical Imaging Conference Record …, 2012
32012
Singles and coincidence processing for a digital PET/MR system using SiPM detectors
B Goldschmidt, CW Lerche, T Solf, A Salomon, F Kiessling, V Schulz
2011 IEEE Nuclear Science Symposium Conference Record, 3922-3924, 2011
32011
Evaluation of PET performance and MR compatibility of a preclinical PET/MR insert with digital silicon photomultiplier technology
P Hallen, D Schug, J Wehner, B Weissler, P Gebhardt, B Goldschmidt, ...
EJNMMI physics 2, 1-1, 2015
22015
PET performance evaluation of a preclinical digital PET/MRI insert
D Schug, C Lerche, P Dueppenbecker, P Gebhardt, B Goldschmidt, ...
EJNMMI physics 1, 1-2, 2014
12014
The system can't perform the operation now. Try again later.
Articles 1–20