Follow
Gil Gerald Lasam Gammad
Gil Gerald Lasam Gammad
Verified email at nus.edu.sg
Title
Cited by
Cited by
Year
Toward self-control systems for neurogenic underactive bladder: a triboelectric nanogenerator sensor integrated with a bistable micro-actuator
F Arab Hassani, RP Mogan, GGL Gammad, H Wang, SC Yen, NV Thakor, ...
ACS nano 12 (4), 3487-3501, 2018
1022018
A flexi‐PEGDA upconversion implant for wireless brain photodynamic therapy
DBL Teh, A Bansal, C Chai, TB Toh, RAJ Tucker, GGL Gammad, Y Yeo, ...
Advanced Materials 32 (29), 2001459, 2020
812020
A 3D printed implantable device for voiding the bladder using shape memory alloy (SMA) actuators
FA Hassani, WYX Peh, GGL Gammad, RP Mogan, TK Ng, TLC Kuo, ...
Advanced Science 4 (11), 1700143, 2017
512017
Nanotunnels within poly (3, 4-ethylenedioxythiophene)-carbon nanotube composite for highly sensitive neural interfacing
N Chen, B Luo, AC Patil, J Wang, GGL Gammad, Z Yi, X Liu, SC Yen, ...
ACS nano 14 (7), 8059-8073, 2020
432020
A wireless multi-channel peripheral nerve signal acquisition system-on-chip
KA Ng, C Yuan, A Rusly, AT Do, B Zhao, SC Liu, WYX Peh, XY Thow, ...
IEEE Journal of Solid-State Circuits 54 (8), 2266-2280, 2019
422019
Design and anchorage dependence of shape memory alloy actuators on enhanced voiding of a bladder
FA Hassani, GGL Gammad, RP Mogan, TK Ng, TLC Kuo, LG Ng, P Luu, ...
Advanced Materials Technologies 3 (1), 1700184, 2018
272018
A 15-channel orthogonal code chopping instrumentation amplifier for area-efficient, low-mismatch bio-signal acquisition
JH Park, T Tang, L Zhang, KA Ng, GGL Gammad, SC Yen, J Yoo
IEEE Journal of Solid-State Circuits 55 (10), 2771-2780, 2020
222020
A 3-Mbps, 802.11 g-based EMG recording system with fully implantable 5-electrode EMGxbrk acquisition device
KA Ng, A Rusly, GGL Gammad, N Le, SC Liu, KW Leong, M Zhang, JS Ho, ...
IEEE Transactions on Biomedical Circuits and Systems 14 (4), 889-902, 2020
14*2020
A fully wireless implantable multi-channel muscle stimulator with closed-loop feedback control
LJ Ong, SC Liu, MDS Wong, T Sibindi, GGL Gammad, CW Tsai, A Rusly, ...
2018 IEEE Biomedical Circuits and Systems Conference (BioCAS), 1-4, 2018
92018
A chronic implantable EMG recording system with wireless power and data transfer
MDS Wong, KA Ng, S Nag, R Jegadeesan, KW Leong, LJ Ong, A Rusly, ...
2017 IEEE Biomedical Circuits and Systems Conference (BioCAS), 1-4, 2017
92017
Flexible sling electrode for bidirectional neural signal recording and selective stimulation
S Lee, SC Yen, LD Liao, GGL Gammad, NV Thakor, C Lee
2016 IEEE 29th International Conference on Micro Electro Mechanical Systems …, 2016
92016
Development of flexible multi-channel muscle interfaces with advanced sensing function
J Wang, Z Xiang, GGL Gammad, NV Thakor, SC Yen, C Lee
Sensors and Actuators A: Physical 249, 269-275, 2016
82016
STEER: 3D printed guide for nerve regrowth control and neural interface in non-human primate model
A Blasiak, KA Ng, MDS Wong, CW Tsai, A Rusly, GGL Gammad, K Voges, ...
IEEE Transactions on Biomedical Engineering 69 (3), 1085-1092, 2021
22021
Photodynamic Therapy: A Flexi‐PEGDA Upconversion Implant for Wireless Brain Photodynamic Therapy (Adv. Mater. 29/2020)
DBL Teh, A Bansal, C Chai, TB Toh, RAJ Tucker, GGL Gammad, Y Yeo, ...
Advanced Materials 32 (29), 2070219, 2020
22020
Neuromodulation of pelvic nerve during early phase of spinal cord injury in rats using implantable prototype devices-a preliminary study
WYX Peh, M Alam, RU Ahmed, S Lee, LJ Ong, S Lu, R Mogan, ...
bioRxiv, 759449, 2019
12019
Integration of a Quantum Tunneling Composite-Based Sensor with the Flexible Actuator for Neurogenic Underactive Bladder
FA Hassani, GGL Gammad, RP Mogan, SC Yen, NV Thakor, C Lee
2018 IEEE 13th Annual International Conference on Nano/Micro Engineered and …, 2018
12018
5–31-Hz 188-/W Light-Sensing Oscillator With Two Active Inductors Fully Integrated on Plastic........................... T. Meister, K. Ishida, S. Knobelspies, G. Cantarella, N …
N Mehta, C Sun, M Wade, V Stojanovic, YS Lee, WH Ho, WZ Chen, D Luo, ...
The system can't perform the operation now. Try again later.