Follow
Yves De Deene
Yves De Deene
Professor of Biomedical Engineering, Medical Physics
Verified email at westernsydney.edu.au
Title
Cited by
Cited by
Year
Polymer gel dosimetry
C Baldock, Y De Deene, S Doran, G Ibbott, A Jirasek, M Lepage, ...
Physics in Medicine & Biology 55 (5), R1, 2010
10192010
Noninvasive MRI Thermometry with the Proton Resonance Frequency (PRF) Method: In Vivo Results in Human Muscle
JD Poorter, CD Wagter, YD Deene, C Thomsen, F Ståhlberg, E Achten
Magnetic resonance in medicine 33 (1), 74-81, 1995
7391995
MRI-based attenuation correction for PET/MRI using ultrashort echo time sequences
V Keereman, Y Fierens, T Broux, Y De Deene, M Lonneux, ...
Journal of nuclear medicine 51 (5), 812-818, 2010
5462010
Benign and malignant musculoskeletal lesions: dynamic contrast-enhanced MR imaging--parametric" first-pass" images depict tissue vascularization and perfusion.
KL Verstraete, Y De Deene, H Roels, A Dierick, D Uyttendaele, M Kunnen
Radiology 192 (3), 835-843, 1994
4221994
A basic study of some normoxic polymer gel dosimeters
Y De Deene, C Hurley, A Venning, K Vergote, M Mather, BJ Healy, ...
Physics in Medicine & Biology 47 (19), 3441, 2002
3522002
The fundamental radiation properties of normoxic polymer gel dosimeters: a comparison between a methacrylic acid based gel and acrylamide based gels
Y De Deene, K Vergote, C Claeys, C De Wagter
Physics in Medicine & Biology 51 (3), 653, 2006
3192006
An investigation of the chemical stability of a monomer/polymer gel dosimeter
Y De Deene, P Hanselaer, C De Wagter, E Achten, W De Neve
Physics in Medicine & Biology 45 (4), 859, 2000
2242000
Three-dimensional dosimetry using polymer gel and magnetic resonance imaging applied to the verification of conformal radiation therapy in head-and-neck cancer
Y De Deene, C De Wagter, B Van Duyse, S Derycke, W De Neve, ...
Radiotherapy and Oncology 48 (3), 283-291, 1998
2231998
The proton-resonance-frequency-shift method compared with molecular diffusion for quantitative measurement of two-dimensional time-dependent temperature distribution in a phantom
J Depoorter, C Dewagter, Y Dedeene, C Thomsen, F Stahlberg, E Achten
Journal of Magnetic Resonance, Series B 103 (3), 234-241, 1994
2011994
Dose–response stability and integrity of the dose distribution of various polymer gel dosimeters
Y De Deene, A Venning, C Hurley, BJ Healy, C Baldock
Physics in Medicine & Biology 47 (14), 2459, 2002
1962002
Dynamic contrast‐enhanced MR imaging of musculoskeletal tumors: Basic principles and clinical applications
KL Verstraete, HJV Woude, PCW Hogendoorn, Y De Deene, M Kunnen, ...
Journal of Magnetic Resonance Imaging 6 (2), 311-321, 1996
1841996
Essential characteristics of polymer gel dosimeters
Y De Deene
Journal of Physics: Conference Series 3 (1), 34, 2004
1772004
Optimization of multiple spin–echo sequences for 3D polymer gel dosimetry
Y De Deene, C Baldock
Physics in Medicine & Biology 47 (17), 3117, 2002
1732002
Validation of MR‐based polymer gel dosimetry as a preclinical three‐dimensional verification tool in conformal radiotherapy
Y De Deene, C De Wagter, B Van Duyse, S Derycke, B Mersseman, ...
Magnetic Resonance in Medicine: An Official Journal of the International …, 2000
1722000
Simulation and experimental verification of the diffusion in an anisotropic fiber phantom
E Fieremans, Y De Deene, S Delputte, MS Özdemir, Y D’Asseler, ...
Journal of magnetic resonance 190 (2), 189-199, 2008
1552008
On the accuracy of monomer/polymer gel dosimetry in the proximity of a high-dose-rate 192Ir source
Y De Deene, N Reynaert, C De Wagter
Physics in Medicine & Biology 46 (11), 2801, 2001
1542001
Whole abdominopelvic radiotherapy (WAPRT) using intensity-modulated arc therapy (IMAT): first clinical experience
W Duthoy, W De Gersem, K Vergote, M Coghe, T Boterberg, Y De Deene, ...
International Journal of Radiation Oncology* Biology* Physics 57 (4), 1019-1032, 2003
1522003
Mathematical analysis and experimental investigation of noise in quantitative magnetic resonance imaging applied in polymer gel dosimetry
Y De Deene, R Van de Walle, E Achten, C De Wagter
Signal Processing 70 (2), 85-101, 1998
1451998
Validation and application of polymer gel dosimetry for the dose verification of an intensity-modulated arc therapy (IMAT) treatment
K Vergote, Y De Deene, W Duthoy, W De Gersem, W De Neve, E Achten, ...
Physics in Medicine & Biology 49 (2), 287, 2004
1342004
Radiological properties of the PRESAGE and PAGAT polymer dosimeters
S Brown, A Venning, Y De Deene, P Vial, L Oliver, J Adamovics, ...
Applied Radiation and Isotopes 66 (12), 1970-1974, 2008
1272008
The system can't perform the operation now. Try again later.
Articles 1–20