Gold nanoparticle‐based brachytherapy enhancement in choroidal melanoma using a full Monte Carlo model of the human eye S Asadi, M Vaez‐zadeh, SF Masoudi, F Rahmani, C Knaup, AS Meigooni Journal of applied clinical medical physics 16 (5), 344-357, 2015 | 56 | 2015 |
Gold nanoparticle‐based brachytherapy enhancement in choroidal melanoma using a full Monte Carlo model of the human eye S Asadi, M Vaez‐zadeh, SF Masoudi, F Rahmani, C Knaup, AS Meigooni Journal of applied clinical medical physics 16 (5), 344-357, 2015 | 56 | 2015 |
Beam shaping assembly optimization of Linac based BNCT and in-phantom depth dose distribution analysis of brain tumors for verification of a beam model F Rahmani, M Shahriari Annals of Nuclear Energy 38 (2-3), 404-409, 2011 | 52 | 2011 |
Design of an epithermal neutron beam for BNCT in thermal column of Tehran research reactor Y Kasesaz, H Khalafi, F Rahmani Annals of Nuclear Energy 68, 234-238, 2014 | 48 | 2014 |
Optimization of Silicon parameters as a betavoltaic battery: Comparison of Si pn and Ni/Si Schottky barrier F Rahmani, H Khosravinia Radiation Physics and Chemistry 125, 205-212, 2016 | 38 | 2016 |
An approach to design a 90Sr radioisotope thermoelectric generator using analytical and Monte Carlo methods with ANSYS, COMSOL, and MCNP A Khajepour, F Rahmani Applied Radiation and Isotopes 119, 51-59, 2017 | 35 | 2017 |
A feasibility study of the Tehran research reactor as a neutron source for BNCT Y Kasesaz, H Khalafi, F Rahmani, A Ezati, M Keyvani, A Hossnirokh, ... Applied Radiation and Isotopes 90, 132-137, 2014 | 34 | 2014 |
Design and optimization of beta-cell temperature sensor based on 63Ni–Si GRG Nejad, F Rahmani, GR Abaeiani Applied Radiation and Isotopes 86, 46-51, 2014 | 32 | 2014 |
Design and construction of a thermal neutron beam for BNCT at Tehran Research Reactor Y Kasesaz, H Khalafi, F Rahmani, A Ezzati, M Keyvani, A Hossnirokh, ... Applied Radiation and Isotopes 94, 149-151, 2014 | 30 | 2014 |
Hybrid photoneutron source optimization for electron accelerator-based BNCT F Rahmani, M Shahriari Nuclear Instruments and Methods in Physics Research Section A: Accelerators …, 2010 | 29 | 2010 |
Optimization of the beam shaping assembly in the D–D neutron generators-based BNCT using the response matrix method Y Kasesaz, H Khalafi, F Rahmani Applied Radiation and Isotopes 82, 55-59, 2013 | 26 | 2013 |
BSA optimization and dosimetric assessment for an electron linac based BNCT of deep‐seated brain tumors F Torabi, S Farhad Masoudi, F Rahmani, FS Rasouli Journal of Radioanalytical and Nuclear Chemistry 300, 1167-1174, 2014 | 23 | 2014 |
Photoneutron production by a 25 MeV electron linac for BNCT application F Torabi, SF Masoudi, F Rahmani Annals of Nuclear Energy 54, 192-196, 2013 | 22 | 2013 |
An investigation into the potential applicability of gel dosimeters for dosimetry in boron neutron capture therapy SM Abtahi, SMR Aghamiri, H Khalafi, F Rahmani Int. J. Radiat. Res 12, 149, 2014 | 19 | 2014 |
Production of a novel high strength heavy concrete using tourmaline and galena for neutron and photon radiation shielding SMR Aghamiri, SMJ Mortazavi, SMA MOSLEH, GM BARADARAN, ... INTERNATIONAL JOURNAL OF RADIATION RESEARCH 12 (3), 277-282, 2014 | 18 | 2014 |
Radiation shielding design of BNCT treatment room for DT neutron source M Pouryavi, SF Masoudi, F Rahmani Applied Radiation and Isotopes 99, 90-96, 2015 | 17 | 2015 |
A novel numerical method to eliminate thickness effect in dual energy X-ray imaging used in baggage inspection A Mazoochi, F Rahmani, FA Davani, R Ghaderi Nuclear Instruments and Methods in Physics Research Section A: Accelerators …, 2014 | 17 | 2014 |
Investigation of the gold nanoparticles effects on the prostate dose distribution in brachytherapy: gel dosimetry and Monte Carlo method H Khosravi, B Hashemi, F Rahmani, A Ebadi Journal of contemporary brachytherapy 8 (5), 422-428, 2016 | 16 | 2016 |
Nedis-Serpent simulation of a neutron source assembly with complex internal heterogeneous structure SV Bedenko, GN Vlaskin, N Ghal-Eh, IO Lutsik, R Irkimbekov, F Rahmani, ... Applied Radiation and Isotopes 160, 109066, 2020 | 14 | 2020 |
FLUKA simulation studies on in–phantom dosimetric parameters of a LINAC–based BNCT N Ghal–Eh, H Goudarzi, F Rahmani Radiation Physics and Chemistry 141, 36-40, 2017 | 13 | 2017 |