Follow
Torsten Wagner
Torsten Wagner
Professor
Verified email at fh-aachen.de
Title
Cited by
Cited by
Year
The light-addressable potentiometric sensor for multi-ion sensing and imaging
T Yoshinobu, H Iwasaki, Y Ui, K Furuichi, Y Ermolenko, Y Mourzina, ...
Methods 37 (1), 94-102, 2005
1752005
“All-in-one” solid-state device based on a light-addressable potentiometric sensor platform
T Wagner, T Yoshinobu, C Rao, R Otto, MJ Schöning
Sensors and Actuators B: Chemical 117 (2), 472-479, 2006
1532006
Handheld multi-channel LAPS device as a transducer platform for possible biological and chemical multi-sensor applications
T Wagner, R Molina, T Yoshinobu, JP Kloock, M Biselli, M Canzoneri, ...
Electrochimica Acta 53 (2), 305-311, 2007
922007
Fabrication of biocompatible lab‐on‐chip devices for biomedical applications by means of a 3D‐printing process
S Takenaga, B Schneider, E Erbay, M Biselli, T Schnitzler, MJ Schöning, ...
physica status solidi (a) 212 (6), 1347-1352, 2015
912015
PLD-prepared cadmium sensors based on chalcogenide glasses—ISFET, LAPS and μISE semiconductor structures
JP Kloock, L Moreno, A Bratov, S Huachupoma, J Xu, T Wagner, ...
Sensors and Actuators B: Chemical 118 (1-2), 149-155, 2006
852006
Light-addressable potentiometric sensors for quantitative spatial imaging of chemical species
T Yoshinobu, K Miyamoto, CF Werner, A Poghossian, T Wagner, ...
Annual Review of Analytical Chemistry 10 (1), 225-246, 2017
702017
Recent developments of chemical imaging sensor systems based on the principle of the light-addressable potentiometric sensor
T Yoshinobu, K Miyamoto, T Wagner, MJ Schöning
Sensors and Actuators B: Chemical 207, 926-932, 2015
702015
Development and characterisation of a compact light-addressable potentiometric sensor (LAPS) based on the digital light processing (DLP) technology for flexible chemical imaging
T Wagner, CF Werner, K Miyamoto, MJ Schöning, T Yoshinobu
Sensors and Actuators B: Chemical 170, 34-39, 2012
642012
Development of a handheld 16 channel pen-type LAPS for electrochemical sensing
MJ Schöning, T Wagner, C Wang, R Otto, T Yoshinobu
Sensors and Actuators B: Chemical 108 (1-2), 808-814, 2005
642005
“LAPS Card”—A novel chip card-based light-addressable potentiometric sensor (LAPS)
T Wagner, C Rao, JP Kloock, T Yoshinobu, R Otto, M Keusgen, ...
Sensors and Actuators B: Chemical 118 (1-2), 33-40, 2006
552006
Influence of experimental factors and film thickness on the measured critical load in the nanoscratch test
BD Beake, AA Ogwu, T Wagner
Materials Science and Engineering: A 423 (1-2), 70-73, 2006
552006
High-speed chemical imaging inside a microfluidic channel
K Miyamoto, A Itabashi, T Wagner, MJ Schöning, T Yoshinobu
Sensors and Actuators B: Chemical 194, 521-527, 2014
522014
Device simulation of the light-addressable potentiometric sensor for the investigation of the spatial resolution
Y Guo, K Miyamoto, T Wagner, MJ Schöning, T Yoshinobu
Sensors and Actuators B: Chemical 204, 659-665, 2014
442014
Chemical imaging of the concentration profile of ion diffusion in a microfluidic channel
K Miyamoto, H Ichimura, T Wagner, MJ Schöning, T Yoshinobu
Sensors and Actuators B: Chemical 189, 240-245, 2013
422013
Light-addressable potentiometric sensors (LAPS): recent trends and applications
T Wagner, MJ Schöning
Comprehensive analytical chemistry 49, 87-128, 2007
382007
Determination of the extracellular acidification of Escherichia coli by a light‐addressable potentiometric sensor
CF Werner, C Krumbe, K Schumacher, S Groebel, H Spelthahn, ...
physica status solidi (a) 208 (6), 1340-1344, 2011
362011
Phase-mode LAPS and its application to chemical imaging
K Miyamoto, T Wagner, T Yoshinobu, S Kanoh, MJ Schöning
Sensors and Actuators B: Chemical 154 (1), 28-32, 2011
362011
Chemical image scanner based on FDM-LAPS
K Miyamoto, Y Kuwabara, S Kanoh, T Yoshinobu, T Wagner, ...
Sensors and Actuators B: Chemical 137 (2), 533-538, 2009
362009
Miniaturized chemical imaging sensor system using an OLED display panel
K Miyamoto, K Kaneko, A Matsuo, T Wagner, S Kanoh, MJ Schöning, ...
Sensors and Actuators B: Chemical 170, 82-87, 2012
352012
High speed and high resolution chemical imaging based on a new type of OLED-LAPS set-up
CF Werner, T Wagner, K Miyamoto, T Yoshinobu, MJ Schöning
Sensors and Actuators B: Chemical 175, 118-122, 2012
342012
The system can't perform the operation now. Try again later.
Articles 1–20