Follow
Dr Vikas Bansal
Dr Vikas Bansal
Associate Professor, Mechanical Engineering, Rajasthan Technical University, Kota
Verified email at rtu.ac.in
Title
Cited by
Cited by
Year
Performance analysis of earth–pipe–air heat exchanger for summer cooling
V Bansal, R Misra, GD Agrawal, J Mathur
Energy and buildings 42 (5), 645-648, 2010
3852010
Performance analysis of earth–pipe–air heat exchanger for winter heating
V Bansal, R Misra, GD Agrawal, J Mathur
Energy and Buildings 41 (11), 1151-1154, 2009
2762009
Targeting for cogeneration potential through total site integration
S Bandyopadhyay, J Varghese, V Bansal
Applied Thermal Engineering 30 (1), 6-14, 2010
1712010
CFD analysis based parametric study of derating factor for Earth Air Tunnel Heat Exchanger
R Misra, V Bansal, GD Agrawal, J Mathur, TK Aseri
Applied Energy 103, 266-277, 2013
1502013
Performance analysis of integrated earth–air-tunnel-evaporative cooling system in hot and dry climate
V Bansal, R Mishra, GD Agarwal, J Mathur
Energy and Buildings 47, 525-532, 2012
1372012
Transient effect of soil thermal conductivity and duration of operation on performance of Earth Air Tunnel Heat Exchanger
V Bansal, R Misra, GD Agarwal, J Mathur
Applied Energy 103, 1-11, 2013
1342013
‘Derating Factor’new concept for evaluating thermal performance of earth air tunnel heat exchanger: A transient CFD analysis
V Bansal, R Misra, GD Agarwal, J Mathur
Applied Energy 102, 418-426, 2013
1132013
Thermal performance investigation of hybrid earth air tunnel heat exchanger
R Misra, V Bansal, GD Agarwal, J Mathur, T Aseri
Energy and Buildings 49, 531-535, 2012
892012
Thermal performance investigation of earth air tunnel heat exchanger coupled with a solar air heating duct for northwestern India
S Jakhar, R Misra, V Bansal, MS Soni
Energy and Buildings 87, 360-369, 2015
882015
Transient analysis based determination of derating factor for earth air tunnel heat exchanger in summer
R Misra, V Bansal, GD Agrawal, J Mathur, T Aseri
Energy and buildings 58, 103-110, 2013
672013
Performance evaluation and economic analysis of integrated earth–air–tunnel heat exchanger–evaporative cooling system
V Bansal, R Misra, GD Agrawal, J Mathur
Energy and Buildings 55, 102-108, 2012
522012
Transient analysis based determination of derating factor for Earth Air Tunnel Heat Exchanger in winter
R Misra, V Bansal, GD Agrawal, J Mathur, T Aseri
Energy and Buildings 58, 76-85, 2013
512013
Optimization of operating parameters of earth air tunnel heat exchanger for space cooling: Taguchi method approach
KK Agrawal, M Bhardwaj, R Misra, G Das Agrawal, V Bansal
Geothermal Energy 6, 1-17, 2018
412018
Performance enhancement of earth air tunnel heat exchanger using evaporative cooling
V Bansal, J Mathur
International Journal of Low-Carbon Technologies 4 (3), 150-158, 2009
382009
Evaluating thermal performance and energy conservation potential of hybrid earth air tunnel heat exchanger in hot and dry climate—in situ measurement
R Misra, V Bansal, G Das Agarwal, J Mathur, T Aseri
Journal of Thermal Science and Engineering Applications 5 (3), 031006, 2013
222013
CFD analysis of thermal influence zone of earth air tunnel heat exchanger under transient conditions
R Misra, TK Aseri, V Bansal
Proceedings of BS2015 14th Conference of International Building Performance …, 2015
152015
Development of passive energy source as earth air pipe heat exchangers (eaphe) system-a review
M VERMA, V Bansal, R Kunj
Journal of Thermal Engineering 6 (5), 651-676, 2020
112020
Review on finite element analysis for estimation of residual stresses in welded structures
BP Mahur, Y Bhardwaj, V Bansal
Materials Today: Proceedings 4 (9), 10230-10234, 2017
52017
A comprehensive review on EATHE
RS Jhala, V Bansal
VII, 530-543, 2016
32016
IInvestigation of Thermal Performance of EATHE System under Intermittent Operation: A CFD Approach
AA Rohit Misra, Vikas Bansal
International Journal of Engineering Technology, Management and Applied …, 2016
32016
The system can't perform the operation now. Try again later.
Articles 1–20