Follow
Reza Ojani
Reza Ojani
Professor of Chemistry, University of Mazandaran
Verified email at umz.ac.ir - Homepage
Title
Cited by
Cited by
Year
Voltammetric determination of ascorbic acid and dopamine in the same sample at the surface of a carbon paste electrode modified with polypyrrole/ferrocyanide films
JB Raoof, R Ojani, S Rashid-Nadimi
Electrochimica Acta 50 (24), 4694-4698, 2005
2072005
Electrocatalytic oxidation of methanol on carbon paste electrode modified by nickel ions dispersed into poly (1, 5-diaminonaphthalene) film
R Ojani, JB Raoof, SRH Zavvarmahalleh
Electrochimica Acta 53 (5), 2402-2407, 2008
1822008
Preparation of polypyrrole/ferrocyanide films modified carbon paste electrode and its application on the electrocatalytic determination of ascorbic acid
JB Raoof, R Ojani, S Rashid-Nadimi
Electrochimica Acta 49 (2), 271-280, 2004
1792004
Carbon Paste Electrode Incorporating 1‐[4‐(Ferrocenyl Ethynyl) Phenyl]‐1‐Ethanone for Electrocatalytic and Voltammetric Determination of Tryptophan
JB Raoof, R Ojani, H Karimi‐Maleh
Electroanalysis: An International Journal Devoted to Fundamental and …, 2008
1652008
Simultaneous electrochemical determination of glutathione and tryptophan on a nano-TiO2/ferrocene carboxylic acid modified carbon paste electrode
JB Raoof, R Ojani, M Baghayeri
Sensors and Actuators B: Chemical 143 (1), 261-269, 2009
1642009
Carbon paste electrode spiked with ferrocene carboxylic acid and its application to the electrocatalytic determination of ascorbic acid
JB Raoof, R Ojani, A Kiani
Journal of Electroanalytical Chemistry 515 (1-2), 45-51, 2001
1612001
MOF-derived Cu/nanoporous carbon composite and its application for electro-catalysis of hydrogen evolution reaction
JB Raoof, SR Hosseini, R Ojani, S Mandegarzad
Energy 90, 1075-1081, 2015
1522015
A highly sensitive electrochemical sensor for simultaneous voltammetric determination of noradrenaline, acetaminophen, xanthine and caffeine based on a flavonoid nanostructured …
M Amiri-Aref, JB Raoof, R Ojani
Sensors and Actuators B: Chemical 192, 634-641, 2014
1422014
Electrocatalytic Determination of Ascorbic Acid at the Surface of 2, 7‐Bis (ferrocenyl ethyl) fluoren‐9‐one Modified Carbon Paste Electrode
JB Raoof, R Ojani, H Beitollahi, R Hossienzadeh
Electroanalysis: An International Journal Devoted to Fundamental and …, 2006
1252006
A highly sensitive electrochemical sensor for simultaneous detection of uric acid, xanthine and hypoxanthine based on poly (l-methionine) modified glassy carbon electrode
R Ojani, A Alinezhad, Z Abedi
Sensors and Actuators B: Chemical 188, 621-630, 2013
1212013
Electrocatalytic oxidation of some carbohydrates by poly (1-naphthylamine)/nickel modified carbon paste electrode
R Ojani, JB Raoof, P Salmany-Afagh
Journal of Electroanalytical Chemistry 571 (1), 1-8, 2004
1192004
L‐Cysteine Voltammetry at a Carbon Paste Electrode Bulk‐Modified with Ferrocenedicarboxylic Acid
JB Raoof, R Ojani, H Beitollahi
Electroanalysis: An International Journal Devoted to Fundamental and …, 2007
1172007
Poly (o-aminophenol) film prepared in the presence of sodium dodecyl sulfate: Application for nickel ion dispersion and the electrocatalytic oxidation of methanol and ethylene …
R Ojani, JB Raoof, S Fathi
Electrochimica Acta 54 (8), 2190-2196, 2009
1152009
Electrocatalytic determination of ascorbic acid at chemically modified carbon paste electrode with 2, 7-bis (ferrocenyl ethynyl) fluoren-9-one
JB Raoof, R Ojani, H Beitollahi
International Journal of Electrochemical Science 2 (7), 534-548, 2007
1102007
Electrocatalytic Oxidation and Highly Selective Voltammetric Determination of L-Cysteine at the Surface of a 1-[4-(Ferrocenyl ethynyl)phenyl]-1-ethanone Modified …
JB Raoof, R Ojani, H Beitollahi, R Hosseinzadeh
Analytical Sciences 22 (9), 1213-1220, 2006
1092006
Catalytic oxidation of ascorbic acid by some ferrocene derivative mediators at the glassy carbon electrode. Application to the voltammetric resolution of ascorbic acid and …
MH Pournaghi-Azar, R Ojani
Talanta 42 (12), 1839-1848, 1995
1071995
Ultrasensitive electrochemical aptasensor based on sandwich architecture for selective label-free detection of colorectal cancer (CT26) cells
AB Hashkavayi, JB Raoof, R Ojani, S Kavoosian
Biosensors and Bioelectronics 92, 630-637, 2017
1052017
Electrocatalytic oxidation of glutathione at carbon paste electrode modified with 2,7-bis (ferrocenyl ethyl) fluoren-9-one: application as a voltammetric sensor
JB Raoof, R Ojani, H Karimi-Maleh
Journal of Applied Electrochemistry 39, 1169-1175, 2009
1052009
A novel voltammetric sensor for amoxicillin based on nickel–curcumin complex modified carbon paste electrode
R Ojani, JB Raoof, S Zamani
Bioelectrochemistry 85, 44-49, 2012
1042012
Simultaneous voltammetric determination of ascorbic acid and dopamine at the surface of electrodes modified with self-assembled gold nanoparticle films
JB Raoof, A Kiani, R Ojani, R Valiollahi, S Rashid-Nadimi
Journal of Solid State Electrochemistry 14, 1171-1176, 2010
1042010
The system can't perform the operation now. Try again later.
Articles 1–20