Metrological management of the high dc resistance scale at INRIM F Galliana, PP Capra, E Gasparotto
Measurement 42 (2), 314-321, 2009
32 2009 The electrical DC resistance scale from 100 k/spl Omega/to 1 T/spl Omega/at IEN F Galliana, G Boella
IEEE Transactions on Instrumentation and Measurement 49 (5), 959-963, 2000
31 2000 Inter-laboratories comparison at 100 GΩ and 1 TΩ level to evaluate the traceability transfer from INRIM in the field of high dc resistance F Galliana, PP Capra, E Gasparotto
Measurement 45 (3), 615-621, 2012
23 2012 Evaluation of two alternative methods to calibrate ultrahigh value resistors at INRIM F Galliana, PP Capra, E Gasparotto
IEEE Transactions on Instrumentation and Measurement 60 (3), 965-970, 2010
23 2010 Traceable technique to calibrate clamp meters in AC current from 100 to 1500 A F Galliana, PP Capra
IEEE Transactions on Instrumentation and Measurement 61 (9), 2512-2518, 2012
19 2012 Analysis of the voltage coefficient of high value standard resistors G Boella, F Galliana
Measurement 41 (1), 1-9, 2008
18 2008 Analysis of a national comparison in the field of electrical low dc resistance F Galliana, E Gasparotto
Measurement 52, 64-70, 2014
15 2014 A traceable technique to calibrate dc current shunts and resistors in the range from 10 μΩ to 10 mΩ F Galliana, PP Capra, E Gasparotto
Measurement 46 (4), 1630-1640, 2013
15 2013 Report of the Italian inter-laboratories comparison of high dc resistance on the calibration of a 10MΩ and a 1GΩ resistors F Galliana, PP Capra, E Gasparotto
Measurement 42 (10), 1532-1540, 2009
15 2009 Accurate comparison between INRIM and a secondary calibration laboratory using a top-class multifunction electrical calibrator F Galliana, M Lanzillotti
Measurement 103, 353-360, 2017
14 2017 Calibration of standard resistors in the field 10 MΩ÷ 1 TΩ by means of a digital multimeter F Galliana, G Boella, PP Capra
Proceedings of IMEKO TC 4, 191-195, 1998
14 1998 Final report on supplementary comparison EURAMET. EM-S32: Comparison of resistance standards at 1 TΩ and 100 TΩ B Jeckelmann, JHN van der Beek, PP Capra, P Chrobok, L Cirneanu, ...
Metrologia 50 (1A), 01008-01008, 2013
12 2013 1 Ω and 10 kΩ high precision transportable setup to calibrate multifunction electrical instruments PP Capra, F Galliana
Measurement 82, 367-374, 2016
11 2016 Automated precision DC voltage fixed ratios divider F Galliana, PP Capra, R Cerri, M Lanzillotti
Measurement 122, 291-296, 2018
10 2018 Compatibility of measurement results within measurement systems using hypotheses tests S D’Emilio, F Galliana, E Arri, G Iuculano
8th, Metrologie 97, 589-594, 1997
10 1997 Comparison of different methods for the calibration of standard resistors in the range 10 MΩ÷ 1 GΩ G Boella, F Galliana
Proc. of 8th, 457-461, 1997
8 1997 Hamon-Guarded Network to Increase the Accuracy of the Transfer of the Resistance Unit up to 1 at INRIM PP Capra, F Galliana
IEEE Transactions on Instrumentation and Measurement 58 (8), 2726-2729, 2009
7 2009 A temperature variable high accuracy 10 kΩ resistor P Capra, C Cassiago, F Galliana, M Astrua
Metrol. Meas. Syst 16, 183-191, 2009
7 2009 Measurement comparisons: A tool to guarantee the reliability of measurement systems and of high-tech industry F Galliana
IEEE Instrumentation & Measurement Magazine 22 (2), 62-66, 2019
6 2019 The strategic role of inter-laboratory comparison among international institutions to assure confidence: report of the INRIM and the European spatial agency comparison on … F Galliana, M Del Moro
MAPAN 33, 77-82, 2018
6 2018