Follow
Robin Hill
Title
Cited by
Cited by
Year
Advances in kilovoltage x-ray beam dosimetry
R Hill, B Healy, L Holloway, Z Kuncic, D Thwaites, C Baldock
Physics in Medicine & Biology 59 (6), R183, 2014
2232014
The water equivalence of solid phantoms for low energy photon beams
R Hill, Z Kuncic, C Baldock
Medical physics 37 (8), 4355-4363, 2010
1212010
Evaluation of the water equivalence of solid phantoms using gamma ray transmission measurements
RF Hill, S Brown, C Baldock
Radiation Measurements 43 (7), 1258-1264, 2008
1142008
A dosimetric evaluation of water equivalent phantoms for kilovoltage x-ray beams
R Hill, L Holloway, C Baldock
Physics in Medicine & Biology 50 (21), N331, 2005
1022005
Investigation of radiological properties and water equivalency of PRESAGE® dosimeters
T Gorjiara, R Hill, Z Kuncic, J Adamovics, S Bosi, JH Kim, C Baldock
Medical Physics 38 (4), 2265-2274, 2011
932011
An evaluation of ionization chambers for the relative dosimetry of kilovoltage x‐ray beams
R Hill, Z Mo, M Haque, C Baldock
Medical physics 36 (9Part1), 3971-3981, 2009
922009
Dosimetry of cone‐defined stereotactic radiosurgery fields with a commercial synthetic diamond detector
JE Morales, SB Crowe, R Hill, N Freeman, JV Trapp
Medical physics 41 (11), 111702, 2014
842014
FlexyDos3D: a deformable anthropomorphic 3D radiation dosimeter: radiation properties
Y De Deene, PS Skyt, R Hil, JT Booth
Physics in Medicine & Biology 60 (4), 1543, 2015
812015
A study of surface dosimetry for breast cancer radiotherapy treatments using Gafchromic EBT2 film
M Nakano, RF Hill, M Whitaker, JH Kim, Z Kuncic
Journal of applied clinical medical physics 13 (3), 83-97, 2012
692012
A comparison of surface doses for very small field size x-ray beams: Monte Carlo calculations and radiochromic film measurements
JE Morales, R Hill, SB Crowe, T Kairn, JV Trapp
Australasian physical & engineering sciences in medicine 37, 303-309, 2014
542014
An experimental extrapolation technique using the Gafchromic EBT3 film for relative output factor measurements in small x‐ray fields
JE Morales, M Butson, SB Crowe, R Hill, JV Trapp
Medical Physics 43 (8Part1), 4687-4692, 2016
462016
Radiological characterization and water equivalency of genipin gel for x-ray and electron beam dosimetry
T Gorjiara, R Hill, Z Kuncic, S Bosi, JB Davies, C Baldock
Physics in Medicine & Biology 56 (15), 4685, 2011
452011
An investigation of backscatter factors for kilovoltage x-rays: a comparison between Monte Carlo simulations and Gafchromic EBT film measurements
J Kim, R Hill, EC Mackonis, Z Kuncic
Physics in Medicine & Biology 55 (3), 783, 2010
402010
A study on the suitability of the PTW microDiamond detector for kilovoltage x-ray beam dosimetry
J Damodar, D Odgers, D Pope, R Hill
Applied Radiation and Isotopes 135, 104-109, 2018
332018
An evaluation of calculation parameters in the EGSnrc/BEAMnrc Monte Carlo codes and their effect on surface dose calculation
JH Kim, R Hill, Z Kuncic
Physics in Medicine & Biology 57 (14), N267, 2012
302012
Study of dosimetric water equivalency of PRESAGE® for megavoltage and kilovoltage x-ray beams
T Gorjiara, R Hill, JH Kim, Z Kuncic, J Adamovics, C Baldock
Journal of Physics: Conference Series 250 (1), 012053, 2010
222010
Flexydos3D: a new deformable anthropomorphic 3D dosimeter readout with optical CT scanning
Y De Deene, R Hill, PS Skyt, J Booth
Journal of Physics: Conference Series 573 (1), 012025, 2015
192015
A study on the use of Gafchromic™ EBT3 film for output factor measurements in kilovoltage X-ray beams
S Gill, R Hill
Australasian physical & engineering sciences in medicine 36, 465-471, 2013
192013
Practical considerations for reporting surface dose in external beam radiotherapy: a 6 MV X-ray beam study
JH Kim, R Hill, Z Kuncic
Australasian physical & engineering sciences in medicine 35, 271-282, 2012
192012
The measurement of backscatter factors of kilovoltage X-ray beams using Gafchromic™ EBT2 film
L Smith, R Hill, M Nakano, J Kim, Z Kuncic
Australasian physical & engineering sciences in medicine 34, 261-266, 2011
192011
The system can't perform the operation now. Try again later.
Articles 1–20