Follow
Adrian Howansky
Adrian Howansky
Verified email at stonybrook.edu
Title
Cited by
Cited by
Year
Toward scintillator high‐gain avalanche rushing photoconductor active matrix flat panel imager (SHARP‐AMFPI): initial fabrication and characterization
JR Scheuermann, A Howansky, M Hansroul, S Léveillé, K Tanioka, ...
Medical physics 45 (2), 794-802, 2018
362018
Comparison of CsI:Tl and Gd2O2S:Tb indirect flat panel detector x‐ray imaging performance in front‐ and back‐irradiation geometries
A Howansky, A Mishchenko, AR Lubinsky, W Zhao
Medical physics 46 (11), 4857-4868, 2019
352019
An apparatus and method for directly measuring the depth‐dependent gain and spatial resolution of turbid scintillators
A Howansky, AR Lubinsky, K Suzuki, S Ghose, W Zhao
Medical physics 45 (11), 4927-4941, 2018
202018
Deriving depth‐dependent light escape efficiency and optical Swank factor from measured pulse height spectra of scintillators
A Howansky, B Peng, AR Lubinsky, W Zhao
Medical physics 44 (3), 847-860, 2017
202017
Direct measurement of Lubberts effect in CsI: Tl scintillators using single x-ray photon imaging
A Howansky, AR Lubinsky, SK Ghose, K Suzuki, W Zhao
Medical Imaging 2017: Physics of Medical Imaging 10132, 61-71, 2017
182017
Solid-state flat panel imager with avalanche amorphous selenium
JR Scheuermann, A Howansky, AH Goldan, O Tousignant, S Levéille, ...
Medical Imaging 2016: Physics of Medical Imaging 9783, 296-304, 2016
152016
Back-irradiated and dual-screen sandwich detector configurations for radiography
AR Lubinsky, A Howansky, H Zheng, W Zhao
Journal of Medical Imaging 6 (3), 033501-033501, 2019
112019
Investigation of random gain variations in columnar CsI: Tl using single x-ray photon imaging
A Howansky, AR Lubinsky, SK Ghose, K Suzuki, W Zhao
Medical Imaging 2018: Physics of Medical Imaging 10573, 180-189, 2018
72018
MO‐AB‐BRA‐07: Low Dose Imaging with Avalanche Amorphous Selenium Flat Panel Imager
J Scheuermann, A Howansky, A Goldan, S Leveille, O Tousignant, ...
Medical Physics 43 (6Part28), 3692-3692, 2016
72016
Evaluation of novel multilayer x-ray detector designs using rapid Monte Carlo simulation
S Dow, A Howansky, W Zhao
Medical Imaging 2018: Physics of Medical Imaging 10573, 147-157, 2018
62018
Scintillating glass‐ceramic substrates for indirect flat panel detectors in digital radiography
RL Leonard, DT Berkowitz, A Thomas, A Howansky, AR Lubinsky, ...
Journal of the American Ceramic Society 103 (12), 6893-6900, 2020
52020
Improved optical quantum efficiency and temporal performance of a flat-panel imager with avalanche gain
C Orlik, AF Howansky, S Léveillé, A Mishchenko, S Kasap, J Stavro, ...
Medical Imaging 2021: Physics of Medical Imaging 11595, 313-320, 2021
42021
Vertical Architecture Solution-Processed Quantum Dot Photodetectors with Amorphous Selenium Hole Transport Layer
A Mukherjee, H Kannan, LT Triet Ho, Z Han, J Stavro, A Howansky, ...
ACS photonics 10 (1), 134-146, 2022
32022
Dual-screen digital radiography with asymmetric reflective screens
A Lubinsky, W Zhao, JA Rowlands, A Howansky
US Patent 11,460,590, 2022
32022
Spatial-frequency-dependent pulse height spectroscopy of x-ray scintillators using single x-ray imaging
S Dow, A Howansky, AR Lubinsky, W Zhao
Medical Imaging 2021: Physics of Medical Imaging 11595, 333-342, 2021
32021
Evaluation of a hybrid direct–indirect active matrix flat-panel imager using Monte Carlo simulation
S Dow, A Howansky, AR Lubinsky, W Zhao
Journal of Medical Imaging 7 (3), 033501-033501, 2020
32020
Investigation of spatial-frequency-dependent noise in columnar CsI: Tl using depth-localized single x-ray imaging
A Howansky, AR Lubinsky, W Zhao
Medical Imaging 2019: Physics of Medical Imaging 10948, 844-850, 2019
32019
Investigation of the screen optics of thick CsI (Tl) detectors
A Howansky, B Peng, K Suzuki, M Yamashita, AR Lubinsky, W Zhao
Medical Imaging 2015: Physics of Medical Imaging 9412, 107-118, 2015
32015
Feasibility of 4D HDR brachytherapy source tracking using x‐ray tomosynthesis: Monte Carlo investigation
R Vasyltsiv, X Qian, Z Xu, S Ryu, W Zhao, A Howansky
Medical Physics 50 (8), 4695-4709, 2023
22023
Feasibility of 4D HDR brachytherapy source tracking using C-arm tomography: Monte Carlo investigation
R Vasyltsiv, X Qian, Z Xu, S Ryu, W Zhao, A Howansky
Medical Imaging 2022: Image-Guided Procedures, Robotic Interventions, and …, 2022
22022
The system can't perform the operation now. Try again later.
Articles 1–20