3D quantification of wall shear stress and oscillatory shear index using a finite-element method in 3D CINE PC-MRI data of the thoracic aorta J Sotelo, J Urbina, I Valverde, C Tejos, P Irarrázaval, ME Andia, S Uribe, ... IEEE transactions on medical imaging 35 (6), 1475-1487, 2016 | 85 | 2016 |
3D axial and circumferential wall shear stress from 4D flow MRI data using a finite element method and a laplacian approach J Sotelo, L Dux‐Santoy, A Guala, J Rodríguez‐Palomares, A Evangelista, ... Magnetic resonance in medicine 79 (5), 2816-2823, 2018 | 62 | 2018 |
Arterial thoracic outlet syndrome: a 32-year experience L Marine, F Valdes, R Mertens, A Kramer, M Bergoeing, J Urbina Annals of Vascular Surgery 27 (8), 1007-1013, 2013 | 55 | 2013 |
Realistic aortic phantom to study hemodynamics using MRI and cardiac catheterization in normal and aortic coarctation conditions J Urbina, JA Sotelo, D Springmüller, C Montalba, K Letelier, C Tejos, ... Journal of Magnetic Resonance Imaging 44 (3), 683-697, 2016 | 47 | 2016 |
Three‐dimensional quantification of vorticity and helicity from 3D cine PC‐MRI using finite‐element interpolations J Sotelo, J Urbina, I Valverde, J Mura, C Tejos, P Irarrazaval, ME Andia, ... Magnetic resonance in medicine 79 (1), 541-553, 2018 | 42 | 2018 |
Variability of 4D flow parameters when subjected to changes in MRI acquisition parameters using a realistic thoracic aortic phantom C Montalba, J Urbina, J Sotelo, ME Andia, C Tejos, P Irarrazaval, ... Magnetic resonance in medicine 79 (4), 1882-1892, 2018 | 38 | 2018 |
Quantification of wall shear stress using a finite-element method in multidimensional phase-contrast MR data of the thoracic aorta J Sotelo, J Urbina, I Valverde, C Tejos, P Irarrázaval, DE Hurtado, S Uribe Journal of Biomechanics 48 (10), 1817-1827, 2015 | 22 | 2015 |
Validation of 4D flow based relative pressure maps in aortic flows D Nolte, J Urbina, J Sotelo, L Sok, C Montalba, I Valverde, A Osses, ... Medical image analysis 74, 102195, 2021 | 15 | 2021 |
Quantification of pulmonary regurgitation in patients with repaired Tetralogy of Fallot by 2D phase-contrast MRI: Differences between the standard method of velocity averaging … J Sotelo, P Bächler, J Urbina, G Crelier, L Toro, M Ferreiro, I Valverde, ... JRSM cardiovascular disease 6, 2048004017731986, 2017 | 6 | 2017 |
Validation of 4D-flow-based pressure difference estimators D Nolte, J Urbina, J Sotelo, L Sok, C Montalba, I Valverde, A Osses, ... Working Paper or Preprint, 2021 | 5 | 2021 |
Open Surgery for Ruptured Abdominal Aortic Aneurysm–38 Years Experience at an Academic Center in Chile L Marine, F Valdes, R Mertens, A Kramer, F Vargas, M Bergoeing, ... Annals of Vascular Surgery 64, 71-79. e1, 2020 | 5 | 2020 |
Mechanical and pharmacomechanical trombolysis in deep venous thrombosis with no clinical response to conventional treatment L Marine, J Urbina, M Bergoeing, F Valdes, R Mertens, A Kramer Revista Medica de Chile 145 (1), 63-71, 2017 | 5 | 2017 |
Trombolisis mecánica y fármaco-mecánica en el tratamiento de trombosis venosa profunda sin respuesta clínica con tratamiento médico convencional L Marine, J Urbina, M Bergoeing, F Valdés, R Mertens, A Kramer Revista médica de Chile 145 (1), 63-71, 2017 | 5 | 2017 |
3D printed valve models replicate in vivo bicuspid aortic valve peak pressure drops H Gill, JF Fernandes, M Bissell, S Wang, J Sotelo, J Urbina, S Uribe, ... Journal of the American College of Cardiology 75 (11_Supplement_1), 1636-1636, 2020 | 4 | 2020 |
A realistic MR compatible aortic phantom to validate hemodynamic parameters from MRI data: aortic coarctation patients comparison using catheterization J Urbina, J Sotelo, C Tejos, P Irarrazaval, ME Andia, R Razavi, I Valverde, ... Journal of Cardiovascular Magnetic Resonance 17 (Suppl 1), P199, 2015 | 4 | 2015 |
3D quantification of hemodynamics parameters of pulmonary artery and aorta using finite-element interpolations in 4D flow MR data JA Sotelo, J Urbina, I Valverde, C Tejos, P Irarrazaval, DE Hurtado, ... Journal of Cardiovascular Magnetic Resonance 17 (Suppl 1), Q27, 2015 | 4 | 2015 |
A realistic MR compatible thoracic aortic phantom to study coarctations using catheterization and cine PC-MRI sequences J Urbina, J Sotelo, I Valverde, M Andía, C Tejos, D Hurtado, P Irarrázabal, ... Stress 5, 20, 2014 | 4 | 2014 |
Manufacturing of Ultrasound-and MRI-Compatible Aortic Valves Using 3D Printing for Analysis and Simulation S Wang, H Gill, W Wan, H Tricker, JF Fernandes, Y Noh, S Uribe, J Urbina, ... Statistical Atlases and Computational Models of the Heart. Multi-Sequence …, 2020 | 2 | 2020 |
3D quantification of Vorticity and Helicity from 4D flow data using finite element interpolations J Sotelo, J Urbina, I Valverde, C Tejos, P Irarrazaval, DE Hurtado, S Uribe Proc. Intl. Soc. Mag. Reson. Med 23, 0453, 2015 | 2 | 2015 |
Validation of 4D flow based relative pressure maps in the aorta D Nolte, J Urbina, J Sotelo, L Sok, C Montalba, I Valverde, A Osses, ... working paper or preprint 74, 102195, 2020 | 1 | 2020 |