Kirk Shelley MD, PhD
Kirk Shelley MD, PhD
Professor of Anesthesiology, Yale University
Verified email at yale.edu - Homepage
Title
Cited by
Cited by
Year
Photoplethysmography: beyond the calculation of arterial oxygen saturation and heart rate
KH Shelley
Anesthesia & Analgesia 105 (6), S31-S36, 2007
4392007
Can photoplethysmography variability serve as an alternative approach to obtain heart rate variability information?
S Lu, H Zhao, K Ju, K Shin, M Lee, K Shelley, KH Chon
Journal of clinical monitoring and computing 22 (1), 23-29, 2008
2572008
Different responses of ear and finger pulse oximeter wave form to cold pressor test
AA Awad, MAM Ghobashy, W Ouda, RG Stout, DG Silverman, KH Shelley
Anesthesia & Analgesia 92 (6), 1483-1486, 2001
1322001
Pulse oximeter waveform: photoelectric plethysmography
K Shelley, S Shelley, C Lake
Clinical monitoring, 420-428, 2001
1292001
What is the best site for measuring the effect of ventilation on the pulse oximeter waveform?
KH Shelley, DH Jablonka, AA Awad, RG Stout, H Rezkanna, ...
Anesthesia & Analgesia 103 (2), 372-377, 2006
1172006
Photoplethysmography
AA Alian, KH Shelley
Best Practice & Research Clinical Anaesthesiology 28 (4), 395-406, 2014
1112014
Estimation of respiratory rate from ECG, photoplethysmogram, and piezoelectric pulse transducer signals: a comparative study of time–frequency methods
S Dash, KH Shelley, DG Silverman, KH Chon
IEEE Transactions on Biomedical Engineering 57 (5), 1099-1107, 2010
892010
The use of joint time frequency analysis to quantify the effect of ventilation on the pulse oximeter waveform
KH Shelley, AA Awad, RG Stout, DG Silverman
Journal of clinical monitoring and computing 20 (2), 81-87, 2006
882006
The effect of venous pulsation on the forehead pulse oximeter wave form as a possible source of error in Spo2 calculation
KH Shelley, D Tamai, D Jablonka, M Gesquiere, RG Stout, DG Silverman
Anesthesia & Analgesia 100 (3), 743-747, 2005
872005
Method of assessing blood volume using photoelectric plethysmography
KH Shelley, DG Silverman, AJ Shelley, RG Stout
US Patent 8,251,912, 2012
862012
The relationship between the photoplethysmographic waveform and systemic vascular resistance
AA Awad, AS Haddadin, H Tantawy, TM Badr, RG Stout, DG Silverman, ...
Journal of clinical monitoring and computing 21 (6), 365-372, 2007
762007
Arterial–pulse oximetry loops: a new method of monitoring vascular tone
KH Shelley, WB Murray, D Chang
Journal of clinical monitoring 13 (4), 223-228, 1997
711997
Virtual environments in healthcare: immersion, disruption, and flow
JM Taekman, K Shelley
International anesthesiology clinics 48 (3), 101-121, 2010
682010
How does the plethysmogram derived from the pulse oximeter relate to arterial blood pressure in coronary artery bypass graft patients?
AA Awad, MAM Ghobashy, RG Stout, DG Silverman, KH Shelley
Anesthesia & Analgesia 93 (6), 1466-1471, 2001
592001
The detection of peripheral venous pulsation using the pulse oximeter as a plethysmograph
KH Shelley, M Dickstein, SM Shulman
Journal of clinical monitoring 9 (4), 283-287, 1993
561993
Crystalline ribosomes are present in brains from senile humans
L O'Brien, K Shelley, J Towfighi, A McPherson
Proceedings of the National Academy of Sciences 77 (4), 2260, 1980
531980
Measuring venous oxygenation using the photoplethysmograph waveform
ZD Walton, PA Kyriacou, DG Silverman, KH Shelley
Journal of clinical monitoring and computing 24 (4), 295-303, 2010
502010
Impact of withdrawal of 450 ml of blood on respiration-induced oscillations of the ear plethysmographic waveform
MJ Gesquiere, AA Awad, DG Silverman, RG Stout, DH Jablonka, ...
Journal of clinical monitoring and computing 21 (5), 277-282, 2007
502007
Statistical approach for the detection of motion/noise artifacts in Photoplethysmogram
N Selvaraj, Y Mendelson, KH Shelley, DG Silverman, KH Chon
2011 Annual International Conference of the IEEE Engineering in Medicine and …, 2011
452011
Analysis of the ear pulse oximeter waveform
AA Awad, RG Stout, MAM Ghobashy, HA Rezkanna, DG Silverman, ...
Journal of clinical monitoring and computing 20 (3), 175-184, 2006
442006
The system can't perform the operation now. Try again later.
Articles 1–20