Follow
Zhipeng Cao
Title
Cited by
Cited by
Year
Numerical evaluation of image homogeneity, signal‐to‐noise ratio, and specific absorption rate for human brain imaging at 1.5, 3, 7, 10.5, and 14T in an 8‐channel transmit …
Z Cao, J Park, ZH Cho, CM Collins
Journal of Magnetic Resonance Imaging 41 (5), 1432-1439, 2015
652015
Radiofrequency field enhancement with high dielectric constant (HDC) pads in a receive array coil at 3.0 T
QX Yang, S Rupprecht, W Luo, C Sica, Z Herse, J Wang, Z Cao, J Vesek, ...
Journal of Magnetic Resonance Imaging 38 (2), 435-440, 2013
652013
Bloch‐based MRI system simulator considering realistic electromagnetic fields for calculation of signal, noise, and specific absorption rate
Z Cao, S Oh, CT Sica, JM McGarrity, T Horan, W Luo, CM Collins
Magnetic resonance in medicine 72 (1), 237-247, 2014
542014
gr-MRI: A software package for magnetic resonance imaging using software defined radios
CJ Hasselwander, Z Cao, WA Grissom
Journal of Magnetic Resonance 270, 47-55, 2016
402016
Array‐compressed parallel transmit pulse design
Z Cao, X Yan, WA Grissom
Magnetic resonance in medicine 76 (4), 1158-1169, 2016
362016
Joint design of large‐tip‐angle parallel RF pulses and blipped gradient trajectories
Z Cao, MJ Donahue, J Ma, WA Grissom
Magnetic resonance in medicine 75 (3), 1198-1208, 2016
342016
Complex difference constrained compressed sensing reconstruction for accelerated PRF thermometry with application to MRI‐induced RF heating
Z Cao, S Oh, R Otazo, CT Sica, MA Griswold, CM Collins
Magnetic Resonance in Medicine 73 (4), 1420-1431, 2015
292015
Simulation verification of SNR and parallel imaging improvements by ICE-decoupled loop array in MRI
X Yan, Z Cao, X Zhang
Applied magnetic resonance 47, 395-403, 2016
282016
Machine learning RF shimming: Prediction by iteratively projected ridge regression
JD Ianni, Z Cao, WA Grissom
Magnetic resonance in medicine 80 (5), 1871-1881, 2018
272018
Experimental implementation of array‐compressed parallel transmission at 7 tesla
X Yan, Z Cao, WA Grissom
Magnetic resonance in medicine 75 (6), 2545-2552, 2016
192016
Tailored spiral in‐out spectral‐spatial water suppression pulses for magnetic resonance spectroscopic imaging
J Ma, C Wismans, Z Cao, DWJ Klomp, JP Wijnen, WA Grissom
Magnetic resonance in medicine 79 (1), 31-40, 2018
182018
Ratio‐adjustable power splitters for array‐compressed parallel transmission
X Yan, Z Cao, WA Grissom
Magnetic resonance in medicine 79 (4), 2422-2431, 2018
162018
| B1+|-selective excitation pulse design using the Shinnar–Le Roux algorithm
WA Grissom, Z Cao, MD Does
Journal of Magnetic Resonance 242, 189-196, 2014
152014
Robust RF shimming and small‐tip‐angle multispoke pulse design with finite‐difference regularization
A Paez, C Gu, Z Cao
Magnetic Resonance in Medicine 86 (3), 1472-1481, 2021
92021
Designing parallel transmit head coil arrays based on radiofrequency pulse performance
Z Cao, X Yan, JC Gore, WA Grissom
Magnetic resonance in medicine 83 (6), 2331-2342, 2020
92020
Frequency encoding by Bloch-Siegert shift
Z Cao, EY Chekmenev, WA Grissom
Proc. 22nd Annu. Meet. Int. Soc. Magn. Res. Med 4220, 2014
92014
Low‐rank plus sparse compressed sensing for accelerated proton resonance frequency shift MR temperature imaging
Z Cao, JC Gore, WA Grissom
Magnetic resonance in medicine 81 (6), 3555-3566, 2019
82019
Slice-selective transmit array pulses for improvement in excitation uniformity and reduction of SAR
BS Park, K Sung, J McGarrity, S Oh, Z Cao, Z Wang, CM Collins
Scientific Research Publishing, 2013
72013
MRI using RF gradients for spatial encoding
W Grissom, M Does, Z Cao
US Patent 9,995,808, 2018
52018
An MRI simulator for effects of realistic field distributions and pulse sequences, including SAR and noise correlation for array coils
Z Cao, CT Sica, S Oh, J McGarrity, T Horan, B Park, CM Collins
Proc 1456, 2010
52010
The system can't perform the operation now. Try again later.
Articles 1–20