Determination of physiological levels of glucose in an aqueous matrix with digitally filtered Fourier transform near-infrared spectra MA Arnold, GW Small Analytical Chemistry 62 (14), 1457-1464, 1990 | 259 | 1990 |
Genetic algorithm-based method for selecting wavelengths and model size for use with partial least-squares regression: application to near-infrared spectroscopy AS Bangalore, RE Shaffer, GW Small, MA Arnold Analytical Chemistry 68 (23), 4200-4212, 1996 | 248 | 1996 |
Noninvasive glucose sensing MA Arnold, GW Small Analytical Chemistry 77 (17), 5429-5439, 2005 | 237 | 2005 |
Measurement of glucose and other analytes in undiluted human serum with near-infrared transmission spectroscopy KH Hazen, MA Arnold, GW Small Analytica Chimica Acta 371 (2-3), 255-267, 1998 | 230 | 1998 |
Near-infrared spectroscopic measurement of physiological glucose levels in variable matrices of protein and triglycerides S Pan, H Chung, MA Arnold, GW Small Analytical chemistry 68 (7), 1124-1135, 1996 | 214 | 1996 |
Temperature-insensitive near-infrared spectroscopic measurement of glucose in aqueous solutions KH Hazen, MA Arnold, GW Small Applied Spectroscopy 48 (4), 477-483, 1994 | 193 | 1994 |
Comparison of combination and first overtone spectral regions for near-infrared calibration models for glucose and other biomolecules in aqueous solutions J Chen, MA Arnold, GW Small Analytical chemistry 76 (18), 5405-5413, 2004 | 182 | 2004 |
Strategies for coupling digital filtering with partial least-squares regression: Application to the determination of glucose in plasma by Fourier-transform near-infrared … GW Small, MA Arnold, LA Marquardt Analytical chemistry 65 (22), 3279-3289, 1993 | 175 | 1993 |
Phantom glucose calibration models from simulated noninvasive human near-infrared spectra MA Arnold, JJ Burmeister, GW Small Analytical chemistry 70 (9), 1773-1781, 1998 | 173 | 1998 |
Near-infrared spectroscopic measurement of glucose in a protein matrix LA Marquardt, MA Arnold, GW Small Analytical Chemistry 65 (22), 3271-3278, 1993 | 153 | 1993 |
Noninvasive blood glucose measurements by near-infrared transmission spectroscopy across human tongues JJ Burmeister, MA Arnold, GW Small Diabetes technology & therapeutics 2 (1), 5-16, 2000 | 145 | 2000 |
Measurement of glucose in water with first-overtone near-infrared spectra KH Hazen, MA Arnold, GW Small Applied Spectroscopy 52 (12), 1597-1605, 1998 | 142 | 1998 |
Scattering and absorption effects in the determination of glucose in whole blood by near-infrared spectroscopy AK Amerov, J Chen, GW Small, MA Arnold Analytical chemistry 77 (14), 4587-4594, 2005 | 139 | 2005 |
Method and apparatus for non-invasive determination of physiological chemicals, particularly glucose GW Small, M Arnold US Patent 6,061,582, 2000 | 125 | 2000 |
Method and apparatus for non-invasive detection of physiological chemicals, particularly glucose GW Small, M Arnold US Patent 5,459,317, 1995 | 117 | 1995 |
Chemometrics and near-infrared spectroscopy: avoiding the pitfalls GW Small TrAC Trends in Analytical Chemistry 25 (11), 1057-1066, 2006 | 112 | 2006 |
Genetic algorithm-based wavelength selection for the near-infrared determination of glucose in biological matrixes: initialization strategies and effects of spectral resolution Q Ding, GW Small, MA Arnold Analytical chemistry 70 (21), 4472-4479, 1998 | 105 | 1998 |
Genetic algorithm-based protocol for coupling digital filtering and partial least-squares regression: application to the near-infrared analysis of glucose in biological matrices RE Shaffer, GW Small, MA Arnold Analytical Chemistry 68 (15), 2663-2675, 1996 | 91 | 1996 |
Detection of atmospheric pollutants by direct analysis of passive Fourier transform infrared interferograms GW Small, RT Kroutil, JT Ditillo, WR Loerop Analytical Chemistry 60 (3), 264-269, 1988 | 87 | 1988 |
Design of optimized finite impulse response digital filters for use with passive Fourier transform infrared interferograms GW Small, AC Harms, RT Kroutil, JT Ditillo, WR Loerop Analytical Chemistry 62 (17), 1768-1777, 1990 | 81 | 1990 |