Volgen
Anthony Waker
Titel
Geciteerd door
Geciteerd door
Jaar
High and Low Fluences of α-Particles Induce a G1 Checkpoint in Human Diploid Fibroblasts
EI Azzam, SM De Toledo, AJ Waker, JB Little
Cancer research 60 (10), 2623-2631, 2000
1422000
Principals of experimental microdosimetry
AJ Waker
Radiation protection dosimetry 61 (4), 297-308, 1995
1081995
Microdosimetry: experimental methods and applications
L Lindborg, A Waker
CRC Press, 2017
732017
Design of tissue-equivalent proportional counters
P Kliauga, AJ Waker, J Barthe
Radiation protection dosimetry 61 (4), 309-322, 1995
531995
Intercomparison of dose equivalent meters based on microdosimetric techniques: detailed analysis and conclusions
HG Menzel, L Lindborg, T Schmitz, H Schuhmacher, AJ Waker
Radiation Protection Dosimetry 29 (1-2), 55-68, 1989
501989
Experimental uncertainties in microdosimetric measurements and an examination of the performance of three commercially produced proportional counters
AJ Waker
Nuclear Instruments and Methods in Physics Research Section A: Accelerators …, 1985
471985
An accelerator based system for in vivo neutron activation analysis measurements of manganese in human hand bones
ML Arnold, FE McNeill, IM Stronach, A Pejovic‐Milic, DR Chettle, A Waker
Medical physics 29 (11), 2718-2724, 2002
462002
Modelling DNA damage induced by different energy photons and tritium beta-particles
VV Moiseenko
International journal of radiation biology 74 (5), 533-550, 1998
451998
Miniature tissue‐equivalent proportional counters for BNCT and BNCEFNT dosimetry
J Burmeister, C Kota, RL Maughan, AJ Waker
Medical physics 28 (9), 1911-1925, 2001
342001
Investigating the TEPC radiation quality factor response for low energy accelerator based clinical applications
Aslam, W V. Prestwich, F E. McNeill, A J. Waker
Radiation protection dosimetry 103 (4), 311-322, 2003
312003
Development of a thick gas electron multiplier for microdosimetry
GM Orchard, K Chin, WV Prestwich, AJ Waker, SH Byun
Nuclear Instruments and Methods in Physics Research Section A: Accelerators …, 2011
302011
Simulation and first test of a microdosimetric detector based on a thick gas electron multiplier
SH Byun, GM Spirou, A Hanu, WV Prestwich, AJ Waker
IEEE Transactions on Nuclear Science 56 (3), 1108-1113, 2009
272009
TEPC performance in the CANDU workplace
AJ Waker, K Szornel, J Nunes
Radiation protection dosimetry 70 (1-4), 197-202, 1997
271997
Design, construction and use of tissue equivalent proportional counters EURADOS report
T Schmitz, AJ Waker, P Kliauga, H Zoetelief
Radiation protection dosimetry 61 (4), 1995
271995
Calculation of radiation-induced DNA damage from photons and tritium beta-particles: Part II: Tritium RBE and damage complexity
VV Moiseenko, AJ Waker, RN Hamm, WV Prestwich
Radiation and Environmental Biophysics 40, 33-38, 2001
252001
Development of an accelerator based determination of aluminum burden in peripheral bone by neutron activation analysis
A Pejovic-Milic, FE McNeill, WV Prestwich, AJ Waker, DR Chettle
Applied radiation and isotopes 49 (5-6), 717-719, 1998
251998
Measurement of the restricted LET of photon sources (5 keV-1.2 MeV) by the recombination method: theory and practice
G Makrigiorgos, AJ Waker
Physics in Medicine & Biology 31 (5), 543, 1986
231986
Neutron microdosimetric response of a gas electron multiplier
J Dubeau, AJ Waker
Radiation protection dosimetry 128 (4), 413-420, 2008
202008
The cellular environment in computer simulations of radiation-induced damage to DNA
VV Moiseenko, RN Hamm, AJ Waker, WV Prestwich
Radiation and environmental biophysics 37, 167-172, 1998
201998
Design of a multi-element TEPC for neutron monitoring
AJ Waker, Aslam, J Lori
Radiation protection dosimetry 143 (2-4), 463-466, 2011
192011
Het systeem kan de bewerking nu niet uitvoeren. Probeer het later opnieuw.
Artikelen 1–20