Volgen
Oscar Martel Fuentes
Oscar Martel Fuentes
Proffessor of Machine Design, Las Palmas de Gran Canaria University
Geverifieerd e-mailadres voor ulpgc.es
Titel
Geciteerd door
Geciteerd door
Jaar
Gyroid porous titanium structures: a versatile solution to be used as scaffolds in bone defect reconstruction
A Yánez, A Cuadrado, O Martel, H Afonso, D Monopoli
Materials & Design 140, 21-29, 2018
1982018
Compressive behaviour of gyroid lattice structures for human cancellous bone implant applications
A Yánez, A Herrera, O Martel, D Monopoli, H Afonso
Materials Science and Engineering: C 68, 445-448, 2016
1472016
Influence of load orientation and of types of loads on the mechanical properties of porous Ti6Al4V biomaterials
A Cuadrado, A Yánez, O Martel, S Deviaene, D Monopoli
Materials & Design 135, 309-318, 2017
892017
Computational study and experimental validation of porous structures fabricated by electron beam melting: A challenge to avoid stress shielding
A Herrera, A Yánez, O Martel, H Afonso, D Monopoli
Materials Science and Engineering: C 45, 89-93, 2014
532014
Surface roughness effects on the fatigue behaviour of gyroid cellular structures obtained by additive manufacturing
A Yánez, MP Fiorucci, A Cuadrado, O Martel, D Monopoli
International Journal of Fatigue 138, 105702, 2020
502020
Fatigue behaviour and equivalent diameter of single Ti-6Al-4V struts fabricated by Electron Bean Melting orientated to porous lattice structures
A Pérez-Sánchez, A Yánez, A Cuadrado, O Martel, N Nuño
Materials & Design 155, 106-115, 2018
382018
Bionic design and verification of 3D printed PEEK costal cartilage prosthesis
C Zhang, L Wang, J Kang, OM Fuentes, D Li
Journal of the Mechanical Behavior of Biomedical Materials 103, 103561, 2020
332020
A new device for the fixation of anterior cruciate ligament tendon grafts: design and experimental study
O Martel, JA Carta, G Garcés
Medical engineering & physics 29 (1), 163-168, 2007
132007
Análisis comparativo de prótesis de cadera: Implantes tradicionales frente a implantes mínimamente invasivos
O Martel, H Alfonso, J Bermejo, A Cuadrado, D Monopoli
Universidad Nacional de Educación a Distancia (España), 2011
122011
The Influence of Dimensions and Powder Recycling on the Roughness and Mechanical Properties of Ti-6Al-4V Parts Fabricated by Laser Powder Bed Fusion
A Yánez, MP Fiorucci, O Martel, A Cuadrado
Materials 15 (16), 5787, 2022
102022
Does thread shape affect the fixation strength of the bioabsorbable interference screws for anterior cruciate ligament reconstructions? A biomechanical study
GL Garcés, O Martel, A Yánez, A Cuadrado
BMC Musculoskeletal Disorders 20, 1-8, 2019
82019
Biomechanical characterization of custom-made dynamic implants fabricated by Electron Beam Melting for anterior chest wall reconstruction
MP Fiorucci, A Cuadrado, A Yanez, O Martel, B Mentado, D Monopoli
Materials & Design 206, 109758, 2021
72021
In Vitro Testing of 2 Adjustable-Loop Cortical Suspensory Fixation Systems Versus Interference Screw for Anterior Cruciate Ligament Reconstruction
GL Garcés, O Martel, A Yánez, I Manchado-Herrera, LM Motta
Orthopaedic Journal of Sports Medicine 9 (9), 23259671211031652, 2021
62021
Does the modelling of the pectus bar affect its stability? Rationale for using a short flat bar
D Pérez, O Martel, A Yánez, JR Cano, A Cuadrado, G Torrent, L López
Interactive CardioVascular and Thoracic Surgery 30 (1), 11-17, 2020
52020
Can an expansion device be used in anterior cruciate ligament reconstruction? An in vitro study of soft tissue graft tibial fixation
O Martel, GL Garcés, A Yánez, A Cuadrado, JF Cárdenes
The Knee 23 (6), 1049-1054, 2016
52016
Influencia de la velocidad en los ensayos de los sistemas de fijación de injertos de ligamento cruzado anterior
O Martel, JF Cárdenes, JA Carta, G Garcés, JM Quintana
88 Congreso Iberoamericano de Ingenierıa mecánica. http://con greso. pucp …, 2011
52011
Influence of the number and position of stripped screws on plate–screw construct biomechanical properties
GL Garcés, A Yánez, A Cuadrado, O Martel
Injury 48, S54-S59, 2017
42017
Experimental analysis of the minimally invasive plate osteosynthesis technique applied with non-locking screws and screw locking elements
A Yanez, A Cuadrado, PJ Cabrera, O Martel, G Garces
Medical engineering & physics 36 (11), 1543-1548, 2014
32014
Influence of the crosshead rate on the mechanical properties of fixation systems of ACL tendon grafts
O Martel, JF Cárdenes, G Garcés, JA Carta
Journal of applied biomechanics 25 (4), 313-321, 2009
32009
Mechanical and permeability properties of skeletal and sheet triply periodic minimal surface scaffolds in bone defect reconstruction
A Yánez, A Cuadrado, O Martel, MP Fiorucci, S Deviaene
Results in Engineering, 101883, 2024
22024
Het systeem kan de bewerking nu niet uitvoeren. Probeer het later opnieuw.
Artikelen 1–20