Follow
Luc Labey
Luc Labey
KU Leuven, Mechanical Engineering Technology TC, Geel, Belgium
Verified email at skynet.be
Title
Cited by
Cited by
Year
Tibial tubercle–posterior cruciate ligament distance: a new measurement to define the position of the tibial tubercle in patients with patellar dislocation
G Seitlinger, G Scheurecker, R Högler, L Labey, B Innocenti, S Hofmann
The American journal of sports medicine 40 (5), 1119-1125, 2012
2512012
Is there a biomechanical explanation for anterior knee pain in patients with patella alta?: influence of patellar height on patellofemoral contact force, contact area and …
T Luyckx, K Didden, H Vandenneucker, L Labey, B Innocenti, J Bellemans
The Journal of Bone & Joint Surgery British Volume 91 (3), 344-350, 2009
2062009
The effect of trochlear dysplasia on patellofemoral biomechanics: a cadaveric study with simulated trochlear deformities
A Van Haver, K De Roo, M De Beule, L Labey, P De Baets, D Dejour, ...
The American journal of sports medicine 43 (6), 1354-1361, 2015
1782015
A common reference frame for describing rotation of the distal femur: a ct-based kinematic study using cadavers
J Victor, D Van Doninck, L Labey, F Van Glabbeek, P Parizel, J Bellemans
The Journal of Bone & Joint Surgery British Volume 91 (5), 683-690, 2009
1562009
Cementing the tibial component in total knee arthroplasty: which technique is the best?
J Vanlommel, JP Luyckx, L Labey, B Innocenti, R De Corte, J Bellemans
The Journal of arthroplasty 26 (3), 492-496, 2011
1542011
The influence of muscle load on tibiofemoral knee kinematics
J Victor, L Labey, P Wong, B Innocenti, J Bellemans
Journal of orthopaedic research 28 (4), 419-428, 2010
1452010
Can medio-lateral baseplate position and load sharing induce asymptomatic local bone resorption of the proximal tibia? A finite element study
B Innocenti, E Truyens, L Labey, P Wong, J Victor, J Bellemans
Journal of orthopaedic surgery and research 4, 1-15, 2009
1032009
Contact forces in several TKA designs during squatting: a numerical sensitivity analysis
B Innocenti, S Pianigiani, L Labey, J Victor, J Bellemans
Journal of biomechanics 44 (8), 1573-1581, 2011
952011
Load sharing and ligament strains in balanced, overstuffed and understuffed UKA. A validated finite element analysis
B Innocenti, ÖF Bilgen, L Labey, GH Van Lenthe, J Vander Sloten, ...
The Journal of arthroplasty 29 (7), 1491-1498, 2014
902014
UKA closely preserves natural knee kinematics in vitro
TJ Heyse, BF El-Zayat, R De Corte, Y Chevalier, L Scheys, B Innocenti, ...
Knee Surgery, Sports Traumatology, Arthroscopy 22, 1902-1910, 2014
842014
The influence of malrotation of the femoral component in total knee replacement on the mechanics of patellofemoral contact during gait: an in vitro biomechanical study
C Verlinden, P Uvin, L Labey, JP Luyckx, J Bellemans, H Vandenneucker
The Journal of Bone & Joint Surgery British Volume 92 (5), 737-742, 2010
832010
Restoration of constitutional alignment in TKA leads to more physiological strains in the collateral ligaments
H Delport, L Labey, B Innocenti, R De Corte, J Vander Sloten, ...
Knee surgery, sports traumatology, arthroscopy 23, 2159-2169, 2015
822015
Posterior Transosseous Capsulotendinous Repair in Total Hip Arthroplasty : A Cadaver Study
W Sioen, JP Simon, L Labey, R Van Audekercke
The Journal of Bone & Joint Surgery 84 (10), 1793-1798, 2002
822002
Post-cam mechanics and tibiofemoral kinematics: a dynamic in vitro analysis of eight posterior-stabilized total knee designs
N Arnout, L Vanlommel, J Vanlommel, JP Luyckx, L Labey, B Innocenti, ...
Knee surgery, sports traumatology, arthroscopy 23, 3343-3353, 2015
732015
Stemmed TKA in a femur with a total hip arthroplasty: is there a safe distance between the stem tips?
M Soenen, M Baracchi, R De Corte, L Labey, B Innocenti
The Journal of arthroplasty 28 (8), 1437-1445, 2013
732013
Cementing the femoral component in total knee arthroplasty: which technique is the best?
M Vaninbroukx, L Labey, B Innocenti, J Bellemans
The Knee 16 (4), 265-268, 2009
732009
The Mark Coventry Award Articular: contact estimation in TKA using in vivo kinematics and finite element analysis
F Catani, B Innocenti, C Belvedere, L Labey, A Ensini, A Leardini
Clinical Orthopaedics and Related Research® 468 (1), 19-28, 2010
722010
Materials selection and design for orthopaedic implants with improved long-term performance
J Vander Sloten, L Labey, R Van Audekercke, G Van der Perre
Biomaterials 19 (16), 1455-1459, 1998
671998
Collateral ligament strains during knee joint laxity evaluation before and after TKA
H Delport, L Labey, R De Corte, B Innocenti, J Vander Sloten, ...
Clinical biomechanics 28 (7), 777-782, 2013
602013
Tibio-femoral kinematics in different total knee arthroplasty designs during a loaded squat: a numerical sensitivity study
S Pianigiani, Y Chevalier, L Labey, V Pascale, B Innocenti
Journal of biomechanics 45 (13), 2315-2323, 2012
552012
The system can't perform the operation now. Try again later.
Articles 1–20