A configurable and low-power mixed signal SoC for portable ECG monitoring applications H Kim, S Kim, N Van Helleputte, A Artes, M Konijnenburg, J Huisken, ... IEEE transactions on biomedical circuits and systems 8 (2), 257-267, 2013 | 294 | 2013 |
CorNET: Deep learning framework for PPG-based heart rate estimation and biometric identification in ambulant environment D Biswas, L Everson, M Liu, M Panwar, BE Verhoef, S Patki, CH Kim, ... IEEE transactions on biomedical circuits and systems 13 (2), 282-291, 2019 | 289 | 2019 |
A 345 µW multi-sensor biomedical SoC with bio-impedance, 3-channel ECG, motion artifact reduction, and integrated DSP N Van Helleputte, M Konijnenburg, J Pettine, DW Jee, H Kim, A Morgado, ... IEEE Journal of Solid-State Circuits 50 (1), 230-244, 2014 | 262 | 2014 |
Time multiplexed active neural probe with 1356 parallel recording sites BC Raducanu, RF Yazicioglu, CM Lopez, M Ballini, J Putzeys, S Wang, ... Sensors 17 (10), 2388, 2017 | 229 | 2017 |
Heart rate estimation from wrist-worn photoplethysmography: A review D Biswas, N Simões-Capela, C Van Hoof, N Van Helleputte IEEE Sensors Journal 19 (16), 6560-6570, 2019 | 228 | 2019 |
A Neural Probe With Up to 966 Electrodes and Up to 384 Configurable Channels in 0.13 m SOI CMOS CM Lopez, J Putzeys, BC Raducanu, M Ballini, S Wang, A Andrei, ... IEEE transactions on biomedical circuits and systems 11 (3), 510-522, 2017 | 213 | 2017 |
A 160 Biopotential Acquisition IC With Fully Integrated IA and Motion Artifact Suppression N Van Helleputte, S Kim, H Kim, JP Kim, C Van Hoof, RF Yazicioglu IEEE transactions on biomedical circuits and systems 6 (6), 552-561, 2012 | 206 | 2012 |
Motion artifact reduction for wrist-worn photoplethysmograph sensors based on different wavelengths Y Zhang, S Song, R Vullings, D Biswas, N Simões-Capela, ... Sensors 19 (3), 673, 2019 | 123 | 2019 |
A 769 μW battery-powered single-chip SoC with BLE for multi-modal vital sign monitoring health patches S Song, M Konijnenburg, R Van Wegberg, J Xu, H Ha, W Sijbers, ... IEEE transactions on biomedical circuits and systems 13 (6), 1506-1517, 2019 | 119 | 2019 |
A Multi(bio)sensor Acquisition System With Integrated Processor, Power Management, LED Drivers, and Simultaneously Synchronized ECG, BIO-Z, GSR, and … M Konijnenburg, S Stanzione, L Yan, DW Jee, J Pettine, R Van Wegberg, ... IEEE Journal of Solid-State Circuits 51 (11), 2584-2595, 2016 | 106 | 2016 |
A multimodal CMOS MEA for high-throughput intracellular action potential measurements and impedance spectroscopy in drug-screening applications CM Lopez, HS Chun, S Wang, L Berti, J Putzeys, C Van Den Bulcke, ... IEEE Journal of Solid-State Circuits 53 (11), 3076-3086, 2018 | 103 | 2018 |
Correlation between electrode-tissue impedance and motion artifact in biopotential recordings D Buxi, S Kim, N Van Helleputte, M Altini, J Wijsman, RF Yazicioglu, ... IEEE sensors journal 12 (12), 3373-3383, 2012 | 95 | 2012 |
18.3 A multi-parameter signal-acquisition SoC for connected personal health applications N Van Helleputte, M Konijnenburg, H Kim, J Pettine, DW Jee, ... 2014 IEEE international solid-state circuits conference digest of technical …, 2014 | 79 | 2014 |
Motion artifact removal using cascade adaptive filtering for ambulatory ECG monitoring system H Kim, S Kim, N Van Helleputte, T Berset, D Geng, I Romero, J Penders, ... 2012 IEEE biomedical circuits and systems conference (BioCAS), 160-163, 2012 | 78 | 2012 |
A reconfigurable, 130 nm CMOS 108 pJ/pulse, fully integrated IR-UWB receiver for communication and precise ranging N Van Helleputte, M Verhelst, W Dehaene, G Gielen IEEE Journal of Solid-State Circuits 45 (1), 69-83, 2009 | 78 | 2009 |
BiometricNet: Deep learning based biometric identification using wrist-worn PPG L Everson, D Biswas, M Panwar, D Rodopoulos, A Acharyya, CH Kim, ... 2018 IEEE International Symposium on Circuits and Systems (ISCAS), 1-5, 2018 | 74 | 2018 |
A 665 μW silicon photomultiplier-based NIRS/EEG/EIT monitoring ASIC for wearable functional brain imaging J Xu, M Konijnenburg, S Song, H Ha, R Van Wegberg, M Mazzillo, ... IEEE transactions on biomedical circuits and systems 12 (6), 1267-1277, 2018 | 72 | 2018 |
A 172 W Compressively Sampled Photoplethysmographic (PPG) Readout ASIC With Heart Rate Estimation Directly From Compressively Sampled Data VR Pamula, JM Valero-Sarmiento, L Yan, A Bozkurt, C Van Hoof, ... IEEE transactions on biomedical circuits and systems 11 (3), 487-496, 2017 | 72 | 2017 |
A flexible system-on-chip (SoC) for biomedical signal acquisition and processing N Van Helleputte, JM Tomasik, W Galjan, A Mora-Sanchez, D Schröder, ... Sensors and Actuators A: Physical 142 (1), 361-368, 2008 | 68 | 2008 |
A compact quad-shank CMOS neural probe with 5,120 addressable recording sites and 384 fully differential parallel channels S Wang, SK Garakoui, H Chun, DG Salinas, W Sijbers, J Putzeys, ... IEEE transactions on biomedical circuits and systems 13 (6), 1625-1634, 2019 | 63 | 2019 |