Follow
Takashi Usuda
Takashi Usuda
NMIJ AIST
Verified email at nifty.com
Title
Cited by
Cited by
Year
Methods for the calibration of vibration pick-ups by laser interferometry: I. Theoretical analysis
M Dobosz, T Usuda, T Kurosawa
Measurement Science and Technology 9 (2), 232, 1998
631998
Calibration of vibration pick-ups with laser interferometry: part IV. Development of a shock acceleration exciter and calibration system
H Nozato, T Usuda, A Oota, T Ishigami
Measurement Science and Technology 21 (6), 065107, 2010
382010
Methods for the calibration of vibration pick-ups by laser interferometry: II. Experimental verification
M Dobosz, T Usuda, T Kurosawa
Measurement Science and Technology 9 (2), 240, 1998
291998
The current progress of measurement standards for vibration in NMIJ/AIST
T Usuda, A Ohta, T Ishigami, O Fuchiwaki, D Misaki, H Aoyama, S Sato
Sixth International Conference on Vibration Measurements by Laser Techniques …, 2004
272004
Theoretical and experimental investigation of transverse sensitivity of accelerometers under multiaxial excitation
T Usuda, C Weißenborn, HJ von Martens
Measurement Science and Technology 15 (5), 896, 2004
232004
Non-contact bio cell manipulation by nonlinear micro flow around the vibrated pipette on micro robot
H Aoyama, N Chiba, O Fuchiwaki, D Misaki, T Usuda
Twenty First American Society for Precision Engineering Annual Meeting, 2006
192006
Operational characteristics of electrostatically driven torsional resonator with two degrees of freedom
T Usuda
Sensors and Actuators A: Physical 64 (3), 255-257, 1998
181998
Desktop micro machining system by multiple micro robots
H Aoyama, O Fuchiwaki, D Misaki, T Usuda
2006 IEEE Conference on Robotics, Automation and Mechatronics, 1-6, 2006
152006
The methods for the calibration of vibration pick-ups by laser interferometry: part V. Uncertainty evaluation on the ratio of transducer's peak output value to peak input …
H Nozato, A Oota, T Ishigami, T Usuda
Measurement Science and Technology 22 (12), 125109, 2011
142011
Development of laser interferometer for a sine-approximation method
T Usuda, E Furuta, A Ohta, H Nakano
Fifth International Conference on Vibration Measurements by Laser Techniques …, 2002
142002
Measurement of piezoelectric constant of ZnO thin film on Si microstructure
K Tanaka, R Kubo, K Ohwada, A Umeda, K Ueda, T Usuda
Japanese journal of applied physics 34 (9S), 5230, 1995
141995
Economic impact of equivalence of measurement standards
T Usuda, A Henson
NCSLI Measure 7 (1), 62-70, 2012
132012
Current status of measurement standards for vibration and shock in NRLM
K Ueda, T Usuda, T Ishigami, T Kurosawa
Fourth International Conference on Vibration Measurements by Laser …, 2000
122000
Evaluation method for frequency characteristics of linear actuators in the sub-m stroke range using a modified Michelson-type interferometer
T Usuda, M Dobosz, T Kurosawa
Nanotechnology 9 (2), 77, 1998
121998
Correction and evaluation of the effect due to parasitic motion on primary accelerometer calibration
A Oota, T Usuda, H Nozato
Measurement 43 (5), 719-725, 2010
112010
Test-location specification by means of hardness mapping on vickers block surface
R Kongkavitool, S Takagi, T Usuda
Proceedings of the Recent Advancement of Theory and Practice in Hardness …, 2007
112007
Development of shock acceleration calibration machine in NMIJ
H Nozato, T Usuda, A Oota, T Ishigami, K Kudo
Proc. of IMEKO TC-22 Symposium, Merida, Mexico (Nov. 2007), 2007
102007
IT security for measuring instruments: confidential checking of software functionality
D Peters, A Yurchenko, W Melo, K Shirono, T Usuda, JP Seifert, F Thiel
Future of Information and Communication Conference, 701-720, 2020
92020
Piezo-impact-driven XY stage and precise sample holder for accurate microlens alignment
Y Irie, H Aoyama, J Kubo, T Fujioka, T Usuda
Journal of Robotics and Mechatronics 21 (5), 635, 2009
92009
Sub-pico liter dispensing mechanism with precise optical gap detector
H Aoyama, T Ekko, Y Adachihara, O Fuchiwaki, D Misaki, Y Irie, S Dejima, ...
Proc. of ASPE2007 Annual meeting 223, 226, 2007
82007
The system can't perform the operation now. Try again later.